7. HOLD-UP TIME
Hold-up Time
typ.
min.
typ.
min.
Fig. 7-1 Hold-up time vs. input voltage
Hold-up Time
80ms
70
60
50
40
30
20
10
0
102 120
a) 24V 10A typ. c) 24V 20A typ.
b) 24V 10A min. d) 24V 20A min.
a
b
c
d
Input Voltage
155
190
230Vac
65ms
55ms
30ms
23ms
at 24V, 10A, 230Vac, see Fig. 7-1
at 24V, 10A, 230Vac, see Fig. 7-1
at 24V, 20A, 230Vac, see Fig. 7-1
at 24V, 20A, 230Vac, see Fig. 7-1
Fig. 7-2 Shut-down behavior, definitions
Input
Voltage
Zero Transition
Output
Voltage
Hold-up Time
- 5%
8. DC-OK RELAY CONTACT
This feature monitors the output voltage, which is produced by the power supply itself. It is independent of a back-fed
voltage from a unit connected in parallel to the power supply output (e.g. redundant application).
Threshold voltage
Contact closes
Contact opens
Contact ratings
Isolation voltage
typ. 21.4V (fixed)
As soon as the output voltage reaches 21.4V.
As soon as the output voltage falls below 21.4V.
max. 60Vdc 0.3A, 30Vdc 1A, 30Vac 0.5A resistive load
min. 1mA at 5Vdc
min. permissible load
See dielectric strength table in section 18.
Fig. 8-1 DC-ok relay contact behavior
Output Voltage
21.4V
open
closed
Jun. 2016 / Rev. 0.2 DS-PIC480.241C-EN
All parameters are specified at 24V, 20A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany