English
Language : 

CP10.121 Datasheet, PDF (15/26 Pages) PULS GmbH – SINGLE PHASE INPUT
CP-Series
CP10.121
12V, 16A, SINGLE PHASE INPUT
17. PROTECTION FEATURES
Output protection
Electronically protected against overload, no-load and short-circuits*)
Output over-voltage protection typ. 18.2Vdc
max. 19Vdc
In case of an internal power supply defect, a redundant
circuit limits the maximum output voltage. The output
shuts down and automatically attempts to restart.
Degree of protection
IP 20
EN/IEC 60529
For use in a controlled environment according to CSA
22.2 No 107.1-01.
Penetration protection
> 4mm
e.g. screws, small parts
Over-temperature protection
yes
Output shut-down with automatic restart
Input transient protection
MOV (Metal Oxide Varistor)
Internal input fuse
included
not user replaceable
*) In case of a protection event, audible noise may occur.
18. SAFETY FEATURES
Input / output separation*)
Class of protection
Isolation resistance
PE resistance
Touch current (leakage current)
*) double or reinforced insulation
SELV
IEC/EN 60950-1
PELV
IEC/EN 60204-1, EN 50178, IEC 62103, IEC 60364-4-41
double or reinforced insulation
I
PE (Protective Earth) connection required
> 5MOhm
input to output, 500Vdc
< 0.1Ohm
PE terminal to housing
typ. 0.14mA / 0.36mA
100Vac, 50Hz, TN-,TT-mains / IT-mains
typ. 0.20mA / 0.50mA
120Vac, 60Hz, TN-,TT-mains / IT-mains
typ. 0.33mA / 0.86mA
230Vac, 50Hz, TN-,TT-mains / IT-mains
max. 0.18mA / 0.43mA
110Vac, 50Hz, TN-,TT-mains / IT-mains
max. 0.26mA / 0.61mA
132Vac, 60Hz, TN-,TT-mains / IT-mains
max. 0.44mA / 1.05mA
264Vac, 50Hz, TN-,TT-mains / IT-mains
Feb. 2016 / Rev. 1.1 DS-CP10.121-EN
All parameters are specified at 12V, 16A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
15/26