CP10.121 Datasheet, PDF (10/26 Pages) PULS GmbH – SINGLE PHASE INPUT
CP-Series
CP10.121
12V, 16A, SINGLE PHASE INPUT
11. LIFETIME EXPECTANCY AND MTBF
AC 100V
AC 120V
AC 230V
Lifetime expectancy*)
155 000h *)
176 000h *)
189 000h *) at 12V, 8A and 40°C
437 000h *)
499 000h *)
534 000h *) at 12V, 8A and 25°C
66 000h
75 000h
97 000h
at 12V, 16A and 40°C
188 000h *)
213 000h *)
275 000h *) at 12V, 16A and 25°C
33 000h
40 000h
57 000h
at 12V, 19.2A and 40°C
94 000h
112 000h
160 000h *) at 12V, 19.2A and 25°C
MTBF**) SN 29500, IEC 61709
587 000h
607 000h
690 000h
at 12V, 16A and 40°C
1 025 000h
1 056 000h
1 185 000h at 12V, 16A and 25°C
MTBF**) MIL HDBK 217F
246 000h
249 000h
278 000h
at 12V, 16A and 40°C;
Ground Benign GB40
333 000h
337 000h
381 000h
at 12V, 16A and 25°C;
Ground Benign GB25
55 000h
55 000h
64 000h
at 12V, 16A and 40°C;
Ground Fixed GF40
70 000h
71 000h
83 000h
at 12V, 16A and 25°C;
Ground Fixed GF25
*) The Lifetime expectancy shown in the table indicates the minimum operating hours (service life) and is determined by the lifetime
expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours and is calculated according to the
capacitor’s manufacturer specification. The manufacturer of the electrolytic capacitors only guarantees a maximum life of up to 15 years
(131 400h). Any number exceeding this value is a calculated theoretical lifetime which can be used to compare devices.
**) MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates reliability of a
device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily represent the life of a product.
The MTBF figure is a statistical representation of the likelihood of a device to fail. A MTBF figure of e.g. 1 000 000h means that
statistically one unit will fail every 100 hours if 10 000 units are installed in the field. However, it cannot be determined if the failed unit
has been running for 50 000h or only for 100h.
12. FUNCTIONAL DIAGRAM
Fig. 12-1 Functional diagram
Output
Voltage
Regulator
VOUT
L
Input Fuse
N
Input Filter
Input Rectifier
PFC
Converter
Power
Converter
Output
Filter
Inrush Current Limiter
+
+
-
-
-
Temper-
ature
Shut-
down
Output
Power
Manager
Output
Over-
Voltage
Protection
DC-ok
Relay
Remote
ON / OFF
(Shut-down)
DC-ok
LED
13
DC-ok
14 Contact
15
ON/
16
OFF
Feb. 2016 / Rev. 1.1 DS-CP10.121-EN
All parameters are specified at 12V, 16A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
10/26