English
Language : 

EPR-89 Datasheet, PDF (5/32 Pages) Power Integrations, Inc. – Engineering Prototype Report for 2.0 W CV Adapter using LNK362P
08-Nov-2005
EP-89 6.2 V, 322 mA Adapter
2 Power Supply Specification
Description
Input
Voltage
Frequency
No-load Input Power (230 VAC)
Output
Output Voltage 1
Output Ripple Voltage 1
Output Current 1
Total Output Power
Continuous Output Power
Efficiency
Full Load
Required average active
efficiency at 25, 50, 75 and 100
% of POUT
Environmental
Conducted EMI
Safety
Surge
Ambient Temperature
Symbol
VIN
fLINE
VOUT1
VRIPPLE1
IOUT1
POUT
η
ηCEC
TAMB
Min Typ Max Units
Comment
85
265 VAC
47 50/60 64
Hz
0.15 W
2 Wire – no P.E.
5.77 6.2 6.63 V
60
mV
322
mA
2.0
W
60
55.2
%
Measured at POUT 115 VAC, 25 oC
%
Per California Energy Commission
(CEC) / Energy Star requirements
Meets CISPR22B / EN55022B
Designed to meet IEC950, UL1950
Class II
1.5
kV
0
40
oC
>6 dB Margin
1.2/50 µs surge, IEC 1000-4-5,
Series Impedance:
Differential Mode: 2 Ω
Common Mode: 12 Ω
Free convection, sea level
Page 5 of 32
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201