English
Language : 

EPR-89 Datasheet, PDF (16/32 Pages) Power Integrations, Inc. – Engineering Prototype Report for 2.0 W CV Adapter using LNK362P
EP-89 6.2 V, 322 mA Adapter
08-Nov-2005
9 Performance Data
All measurements performed at room temperature (25 °C), 60 Hz input frequency.
9.1 Efficiency
68
66
64
62
60
85 VAC
115 VAC
58
230 VAC
265 VAC
56
54
0
0.5
1
1.5
2
2.5
Output Power (W)
Figure 6 – Efficiency vs. Output Power.
% of Full Load
25
50
75
100
Average Efficiency
CEC Requirement
% Efficiency @
115 VAC
63.3
65.2
64.9
64.9
64.6
% Efficiency @
230VAC
58.2
61.4
63.0
63.2
61.5
55.2
Figure 7 – Efficiency vs. Input Voltage and Load, Room Temperature, 60 Hz.
9.1.1 Active Mode Efficiency (CEC) Measurement Data
All single output adapters, including those provided with products, for sale in California
after July 1st, 2006 must meet the California Energy Commission (CEC) requirement for
minimum active mode efficiency and no-load input power consumption. Minimum active
mode efficiency is defined as the average efficiency at 25, 50, 75 and 100% of rated
output power, based on the nameplate rated output power of the supply.
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
Page 16 of 32