EP-89 6.2 V, 322 mA Adapter
08-Nov-2005
12 Line Surge
Differential input line 1.2/50 µs surge testing was completed on a single test unit to
IEC61000-4-5. Input voltage was set at 230 VAC / 60 Hz. Output was loaded at full load
and operation was verified following each surge event.
Surge
Level (V)
+500
-500
+750
-750
+1000
-1000
+1500
-1500
Input
Voltage
(VAC)
230
230
230
230
230
230
230
230
Injection
Location
L to N
L to N
L to N
L to N
L to N
L to N
L to N
L to N
Injection Test Result
Phase (°) (Pass/Fail)
90
Pass
90
Pass
90
Pass
90
Pass
90
Pass
90
Pass
90
Pass
90
Pass
Unit passes under all test conditions.