English
Language : 

EPR-89 Datasheet, PDF (27/32 Pages) Power Integrations, Inc. – Engineering Prototype Report for 2.0 W CV Adapter using LNK362P
08-Nov-2005
EP-89 6.2 V, 322 mA Adapter
13 Conducted EMI
Power Integrations
27.Oct 05 15:50
dBµV 80
70
1 QP
EN55022Q
CLRWR
60
2 AV
EN55022A
CLRWR
50
Att 10 dB AUTO
1 MHz
RBW
9 kHz
Marker 1 [T1 ]
MT
500 ms
35.01 dBµV
PREAMP OFF
182.849162999 kHz
10 MHz
LIMIT CHECK MARG
LINE EN55022A MARG
LINE EN55022Q MARG
SGL
TDF
40
1
30
20
10
0
-10
-20
150 kHz
30 MHz
DAK 89: 115VAC with ARTIFICIAL HAND
Date: 27.OCT.2005 15:50:22
Figure 27 – Conducted EMI, Maximum Steady State Load,
115 VAC, 60 Hz, Artificial Hand and EN55022 B Limits.
Power Integrations
27.Oct 05 16:02
dBµV 80
70
1 QP EN55022Q
CLRWR
60
2 AV EN55022A
CLRWR
50
Att 10 dB AUTO
RBW
9 kHz Marker 1 [T1 ]
MT
500 ms
29.68 dBµV
PREAMP OFF
182.849162999 kHz
1 MHz
10 MHz
LIMIT CHECK MARG
LINE EN55022A MARG
LINE EN55022Q MARG
SGL
TDF
40
1
30
20
10
0
-10
-20
150 kHz
30 MHz
DAK 89: 230VAC with ARTIFICIAL HAND
Date: 27.OCT.2005 16:02:19
Figure 28 – Conducted EMI, Maximum Steady State Load,
230 VAC, 60 Hz, Artificial Hand and EN55022 B Limits.
Page 27 of 32
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com