English
Language : 

EPR-89 Datasheet, PDF (20/32 Pages) Power Integrations, Inc. – Engineering Prototype Report for 2.0 W CV Adapter using LNK362P
EP-89 6.2 V, 322 mA Adapter
08-Nov-2005
9.4.2 Line
7
6.5
6
5.5
5
0
50
100
150
200
250
300
Input Voltage (VAC)
Figure 11 – Line Regulation, Room Temperature, Full Load.
10 Thermal Performance
Thermal performance was measured inside a plastic enclosure, at full load, with no
airflow over the power supply components or the housing they were enclosed within.
Item
Ambient
LNK362P
(source pin)
90 VAC
40°C
93.0°C at 2.0 W output
(6.2V, 322mA)
265 VAC
40°C
111.8°C at 2.0 W output
(6.2V, 322mA).
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
Page 20 of 32