English
Language : 

EPR-89 Datasheet, PDF (22/32 Pages) Power Integrations, Inc. – Engineering Prototype Report for 2.0 W CV Adapter using LNK362P
EP-89 6.2 V, 322 mA Adapter
11 Waveforms
11.1 Drain Voltage and Current, Normal Operation
08-Nov-2005
Figure 13 – 85 VAC, Full Load.
Upper: IDRAIN, 0.1 A / div.
Lower: VDRAIN, 100 V / div.
11.2 Output Voltage Start-up Profile
Figure 14 – 265 VAC, Full Load.
Upper: IDRAIN, 0.1 A / div.
Lower: VDRAIN, 200 V / div.
Figure 15 – Start-up Profile, 115 VAC.
1 V, 20 ms / div.
Figure 16 – Start-up Profile, 230 VAC.
1 V, 20 ms / div.
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
Page 22 of 32