11.3 Drain Voltage and Current Start-up Profile
EP-89 6.2 V, 322 mA Adapter
Figure 17 – 85 VAC Input and Maximum Load.
Upper: IDRAIN, 0.1 A / div.
Lower: VDRAIN, 100 V & 1 ms / div.
Figure 18 – 265 VAC Input and Maximum Load.
Upper: IDRAIN, 0.1 A / div.
Lower: VDRAIN, 200 V & 1 ms / div.
11.4 Load Transient Response (75% to 100% Load Step)
Figure 19 – Transient Response, 115 VAC, 100-75-
100% Load Step.
Output Voltage
50 mV, 20 ms / div.
Figure 20 – Transient Response, 230 VAC, 100-75-
100% Load Step.
Output Voltage
50 mV, 20 ms / div.
Page 23 of 32