English
Language : 

EQ2660-9R Datasheet, PDF (9/26 Pages) Power-One – Q Series Data Sheet 66 – 132 Watt DC-DC Converters
Q Series Data Sheet
®
66 – 132 Watt DC-DC Converters
Table 5b: Output data for double-output models with both outputs in parallel configuration. General conditions as per table 5a
Output
Characteristics
Vo1 Setting voltage of 1st output
Vow Worstcase output voltage
Vo P Overvoltage limitation
of second control loop
Io
Output current 2
Io nom Nominal output current
IoL
Output current limit 2
vo 4 Output
Switch. frequ.
voltage noise Total incl. spikes
Po max Output power 1
vo d 4
td 4 5
Vo os
Vo tr
αVo
Dynamic Voltage deviation
load
regulation Recovery time
Dynamic line regulation
(output overshoot)
Output via R-input
voltage
trim range using opt. P 1
Temp. coefficient of Vo
Conditions
Vi nom, Io nom
Vi min – Vi max
TC min – TC max
Io = 0 – Io max
Vi min – Vi max
TC min – TC max
Vi nom, Io nom
BW = 20 MHz
Vi min – Vi max
TC min – TC max
Vi nom
I o nom ↔ 1/2 Io nom
0 ↔ Vi max
0 – Io max
1.1 • Vi min – Vi max
0.1 • Io nom – Io nom
TC min – TC max
Io nom, TC min –TC max
48Q /BQ – GQ2540
15 V
48Q /BQ – GQ2660
24 V
min
typ
max min
typ
max
14.93
15.08 23.88
24.12
14.78
15.23 23.64
24.36
17
19 27.5
30
0
6.9/8.4 3
6.6/8.03 0
6.6
4.4
8.6/10.43 4.6/5.753
10
20
10
20
40
20
99/120 3
106/132 3
4.4 /5.53
6.2 /8.03
25
40
±200
1500
0.8
±600
800
1.2
9.0
16.5 14.46
26.4
13.5
16.5 21.6
26.4
±0.02
±0.02
Unit
V
A
mVpp
W
mV
µs
V
%/K
1 If the output voltages are increased above Vo nom through R-input control, option P setting or remote sensing, the output power should be
reduced accordingly so that Po max and TC max are not exceeded.
2 See Output Power at Reduced Temperature.
3 First value for 48Q, 2nd value for BQ – GQ
4 According to IEC/EN 61204
5 Recovery time until Vo remains within ±1% of Vo, see Dynamic load regulation.
6 For DQ2660 and EQ2660: 16.8 V
BCD20011- G Rev AG, 12-Mar-2012
Page 9 of 26