English
Language : 

EQ2660-9R Datasheet, PDF (10/26 Pages) Power-One – Q Series Data Sheet 66 – 132 Watt DC-DC Converters
Q Series Data Sheet
®
66 – 132 Watt DC-DC Converters
Table 6a: Output data for double-output models with output 1 and output 2 in symmetrical or independent configuration.
General conditions as per table 5a.
Output
48Q / BQ – GQ2320
12 V /12 V
48Q / BQ – GQ2540
15 V /15 V
Unit
Characteristics
Conditions
Output 1
Output 2
Output 1
Output 2
min typ max min typ max min typ max min typ max
Vo
Output setting voltage1 Vi nom, Io nom 11.94
12.06 11.88
12.12 14.93
15.08 14.85
15.15 V
Vow Worstcase output
Vi min – Vi max 11.82
12.18
see Output 14.78
15.23
see Output
voltage
TC min – TC max
Voltage Regulation
Voltage Regulation
Vo P Overvoltage limitation Io = 0 – Io max
n.a.
13.5
15
n.a.
17
19
of second control loop
Io
Io nom
Io L
vo 4
Output current 2
Vi min – Vi max
0.8
7.2/9.23 0.8
7.2/9.23 0.6
6.0/7.43 0.6
Nominal output current TC min – TC max
4.0
4.0
3.3
6.0/7.43 A
3.3
Output current limit 2
8.4/10.53 10.4/133 8.4/10.53 10.4/133 6.9/8.4 3 8.6/10.4 3 6.9/8.43 8.6/10.43
Output Switch. frequ. Vi nom, Io nom
voltage
BW = 20 MHz
noise Total incl.spikes
8 16
16 40
8 16
16 40
8 16
16 40
8
16 mVpp
16 40
Po max Output power total1
vo d 4
td 4 5
Dynamic Voltage
load
deviation
regulation Recovery
time
Vi min – Vi max
TC min – TC max
Vi nom
Io nom ↔ 1/2 Io nom
I o2 = 1/2 Io nom
96 /1203
±200
±300
1500
99 /120 3
W
±200
±300
mV
1500
µs
Vo tr
αVo
Output via R-input 1.1•Vi min – Vi max 7.2
voltage
0.1• Io nom – Io nom
trim range using opt. P TC min – TC max 10.8
Temp. coefficient of Vo Ionom
TC min –TC max
±0.02
13.2 see Output
Voltage Regulation
13.2
±0.02
9.0
16.5
13.5
16.5
±0.02
see Output
Voltage Regulation
±0.02
V
%/K
1 If the output voltages are increased above Vo nom through R-input control, option P setting, or remote sensing, the output power should
be reduced accordingly so that Po max and TC max are not exceeded.
2 See Output Power at Reduced Temperature.
3 First value for 48Q, 2nd value for BQ – GQ
4 According to IEC/EN 61204
5 Recovery time until Vo remains within ±1% of Vo, see Dynamic load regulation.
6 Io nom = Io1 + Io2
BCD20011- G Rev AG, 12-Mar-2012
Page 10 of 26
www.power-one.com