EQ2660-9R Datasheet, PDF (25/26 Pages) Power-One – Q Series Data Sheet 66 – 132 Watt DC-DC Converters
Q Series Data Sheet
®
66 – 132 Watt DC-DC Converters
Table 21: Safety concept leading to an SELV output circuit
Conditions Front end
DC-DC converter
Result
Nominal
supply
voltage
Mains
≤150 VAC
Minimum required grade
of insolation, to be pro-
vided by the AC-DC front
end, including mains-
supplied battery charger
Functional (i.e. there is
no need for electrical iso-
lation between the mains
supply circuit and the
DC-DC converter input
circuit)
Maximum DC Minimum required Types
output voltage safety status of the
from the front front end output
end 1
circuit
≤150 V 2
Primary circuit
DQ
EQ
Measures required to achieve Safety status
the specified safety status of of the DC-DC
the output circuit
converter
output
circuit
Double or reinforced insula-
tion, based on 150 VAC and
DC (provided by the con-
verter) and earthed case 3
SELV circuit
Basic
≤60 V
ELV circuit
BQ, GQ
48Q
CQ
Supplementary insulation,
based on 150 VAC (provided
by the DC-DC converter)
and earthed case 3
≤75 V
Hazardous voltage 48Q
secondary circuit CQ
Supplementary insulation,
based on 150 VAC and
double or reinforced insula-
tion 4 (both provided by the
DC-DC converter) and
earthed case 3
Mains
≤ 250 VAC
≤ 60 V
Earthed SELV
circuit 3
BQ, GQ Functional insulation (provided
48Q,CQ by the converter)
≤ 75 V
ELV circuit
Unearthed
48Q
hazardous voltage CQ
secondary circuit
Input fuse 5, output suppressor
diodes 6, earthed output
circuit 3 and earthed 3 or non
user-accessible case
Earthed
SELV circuit
≤150 V 2
Earthed hazardous
voltage secondary
circuit 3 or earthed
ELV circuit 3
BQ, GQ Double or reinforced
48Q, CQ insulation 4 (provided by
DQ
the converter)
EQ
and earthed case 3
SELV circuit
Unearthed
DQ
hazardous voltage EQ
secondary circuit
Supplementary insulation, ba-
sed on 250 VAC and double
or reinforced insulation 4 (both
provided by the converter)
and earthed case 3
Double or reinforced
≤ 60 V
SELV circuit
BQ, 48Q Functional insulation (provi-
CQ, GQ ded by the converter)
≤120 V
≤150 V 2
TNV-2 circuit
Double or re-infor-
ced insulated un-
earthed hazardous
voltage secondary
circuit 7
48Q, CQ Basic insulation 4 (provided
DQ
by the converter)
EQ
1 The front end output voltage should match the specified input voltage range of the DC-DC converter.
2 The maximum rated input voltage of EQ models acc. to IEC/EN 60950 is 150 V. Power-One specifies the tolerance as +12% (max. 168 V)
3 The earth connection has to be provided by the installer according to IEC/EN 60950.
4 Based on the maximum rated output voltage provided by the front end.
5 The installer shall provide an approved fuse with the lowest rating suitable for the application in a non-earthed input conductor directly at
the input of the DC-DC converter (see fig. Schematic safety concept). For UL’s purposes, the fuse needs to be UL-listed.
6 Each suppressor diode should be dimensioned such that in the case of an insulation fault the diode is able to limit the output voltage to
SELV (<60 V), until the input fuse blows (see fig. Schematic safety concept).
7 Has to be insulated from earth according to IEC/EN 60950, by at least supplementary insulation, based on the maximum nominal output
voltage from the front end.
BCD20011- G Rev AG, 12-Mar-2012
Page 25 of 26