EQ2660-9R Datasheet, PDF (24/26 Pages) Power-One – Q Series Data Sheet 66 – 132 Watt DC-DC Converters
Q Series Data Sheet
®
66 – 132 Watt DC-DC Converters
Table 19: Isolation
Characteristic
Electric
strength
tests
Factory test ≥1 s
AC test voltage equivalent
to factory test
Insulation resistance
Minimum creepage distances
Input to
case + output(s)
2.1 1
1.5 1
Output(s) to
case
2.1
1.5
Output
to output
0.5*
0.35*
Out-OK to
case + input
2.1 1
1.5 1
Out-OK
to output(s)
2.1 1
1.5 1
Unit
kVDC
kVAC
>300 2
1.4 3
>300 2
1.4
>100
>300 2
>300 2
MΩ
mm
* Models with version V104 or higher. Older converters have only been tested with 0.3 kVDC.
1 In accordance with EN 50116 and IEC/EN 60950, subassemblies connecting input to output are pre-tested with 4.2 kVDC.
2 Tested at 500 VDC.
3 2.8 mm between input and output.
• Connecting the input to a circuit, which is subject to a
maximum transient rating of 1500 V.
CB Scheme is available.
The converters are subject to manufacturing surveillance in
accordance with the above mentioned standards and with ISO
9001:2000.
(max. 0.1 Ω) and the electric strength test (table 19) are
performed in the factory as routine tests in accordance with EN
50116 and IEC/EN 60950-1, and should not be repeated in the
field. Power-One will not honor any warranty claims resulting
from electric strength field tests.
Safety of Operator-Accessible Output Circuits
Railway Applications
The Q Series converters have been designed by observing the
railway standards EN 50155, EN 50121-3-2, and EN 50121-4.
All boards are coated with a protective lacquer.
The converters comply with class S1 of the fire protection
standard E DIN 5510-2 (Oct. 2007).
Isolation and Protective Earth
The test of the resistance of the protective earthing circuit
If the output circuit of a DC-DC converter is operator-
accessible, it shall be an SELV circuit according to IEC 60950.
Table 21 shows some possible installation configurations,
compliance with which causes the output circuit of the DC-DC
converter to be SELV up to a configured output voltage (sum of
nominal voltages, if in series configuration) of 35 V.
However, it is the sole responsibility of the installer to ensure
the compliance with the relevant and applicable safety
regulations.
Description of Options
Option P: Output Voltage Adjustment
Option P provides a built-in multi-turn potentiometer, which
allows an output voltage adjustment of ±10% of Vo nom. The
potentiometer is accessible through a hole in the front cover.
With double-output models, both outputs are affected by the
potentiometer. If converters are parallel-connected, their in-
dividual output voltage should be set within a tolerance of ±1%.
If Vo is set higher than Vo nom, the output currents should be
~
Mains
~
AC-DC
front
end
Fuse
+ Battery
Fuse
DC-DC
con-
verter
Suppressor
diode
10026
+
SELV
–
Earth
Earth
Earth
Fig. 27
connection
connection connection
Schematic safety concept
Use fuse, suppressor diode and earth connections as per
table 21. For fuse(s), required by the application; see
Installation Instructions.
reduced accordingly, so that the maximum specified output
power is not exceeded.
Option -7: Temperature Range
Option -7 designates converters with an operational ambient
temperature range of – 25 to 71 °C. Not for new designs.
Option B, B1: Additional Heat Sink
Thickness: 12.5 mm (opt. B) or 20 mm (opt. B1)
Table 20:Thermal resistance case to ambient (approx.values)
Case
Thermal resistance Thickness of case
Standard (160 mm long)
Case 220mmlong 1 2
Option B 2
Option B1
1.6 K/W
1.4 K/W
1.45 K/W
1.4 K/W
< 20 mm
< 20 mm
< 33 mm
< 40 mm
1 As well available with an additional heat sink
2 Customer-specific models. Add 5000 to the part number!
Option G:
RoHS compliant for all six substances.
BCD20011- G Rev AG, 12-Mar-2012
Page 24 of 26