English
Language : 

EQ2660-9R Datasheet, PDF (19/26 Pages) Power-One – Q Series Data Sheet 66 – 132 Watt DC-DC Converters
Q Series Data Sheet
®
66 – 132 Watt DC-DC Converters
Electromagnetic Compatibility (EMC)
A metal oxide VDR together with an input fuse and a sym-
metrical input filter form an effective protection against high
input transient voltages, which typically occur in most
installations, especially in battery-driven mobile applications.
The Q Series has been successfully tested to the following
specifications:
Electromagnetic Immunity
Table 13: Immunity type tests
Phenomenon
Supply related
surge
Direct transients
Indirect coupled
transients
Electrostatic
discharge
(to case)
Electromagnetic
field
Electrical fast
transient s/burst
Surges
Conducted
disturbances
Power frequency
magnetic field
Standard Level
Coupling
mode1
Value
applied
Waveform
Source
imped.
Test
procedure
In Perf.
oper. crit. 2
RIA 12
EN 50155
RIA 12
EN 50155:
1995
IEC/EN
61000-4-2
B
+i/– i
1.5 • Vbatt
0.1/1/0.1 s
0.2 Ω
1 positive
yes A
1.4 • Vbatt
1Ω
surge
D4
–i/c, +i/–i
G5
1800 Vp
5/50 µs
5 Ω 5 pos. and 5 neg. yes A
8400 Vp
0.05/ 0.1 µs
100 Ω
impulses
H –o/c, +o/–o, –o/–i 1800 Vp
5/50 µs
L
8400 Vp
0.05/0.1 µs
46 contact discharge ±8000 Vp
air discharge ±15000 Vp
1/50 ns
330 Ω 10 positive and yes A
10 negative
discharges
IEC/EN
x7
61000-4-3
8
antenna
antenna
20 V/m 80% AM, 1 kHz n.a.
80 – 1000 MHz yes A
20 V/m 80% AM, 1 kHz n.a. 800 – 1000 MHz yes A
10 V/m
1400 – 2100 MHz
5 V/m
2100 – 2500 MHz
IEC/EN
61000-4-4:
2004
IEC/EN
61000-4-5
3 9 direct coupl. (fig. 9)9 ±2000 Vp9 bursts of 5/50 ns
4
+i/c, –i/c,+i/–i
±4000 Vp
5 kHz over 15 ms
burst period: 300
3 capacit. (fig.10)9, o/c ±2000 Vp
ms
50 Ω
60 s positive
yes A
60 s negative
yes
B
transients per
coupling mode yes B
33
+i/c, –i/c
±2000 Vp3
1.2/50 µs
12 Ω 5 pos. and 5 neg. yes B
23
+i/–i
±1000 Vp3
2Ω
surges per
coupling mode
FTZ 19 Pfl 1 10
+i/–i
150 Vp
0.1/0.3 ms <100 A 3 pos. 5 repetitions yes A
IEC/EN
61000-4-6
3 11 i, o, signal wires 10 VAC
(140 dBµV)
AM 80%
1 kHz
150 Ω 0.15 – 80 MHz yes A
IEC/EN
12
61000-4-8
100 A/m
60 s in all 3 axis yes A
1 i = input, o = output, c = case.
2 A = Normal operation, no deviation from specs, B = Temporary deviation from specs possible.
3 Measured with an external input capacitor specified in table 4. Exceeds EN 50121-3-2:2006 table 7.3 and EN 50121-4:2006 table 2.3.
4 Corresponds to EN 50155:2001, waveform A, and EN 50121-3-2:2000 table 7.2.
5 Corresponds to EN 50155:2001, waveform B.
6 Exceeds EN 50121-3-2:2006 table 9.3 and EN 50121-4:2006 table 1.4.
7 Corresponds to EN 50121-3-2:2006 table 9.1 and exceeds EN 50121-4:2006 table 1.1; valid for version V104 or higher.
8 Corresponds to EN 50121-3-2:2006 table 9.2 and EN 50121-4:2006 table 1.2 (compliance with digital mobile phones). Valid for converters
with version V104 or higher.
9 Corresponds to EN 50121-3-2:2006 table 7.2 and EN 50121-4:2006 table 2.2; valid for converters with version V104 or higher.
10 Valid for 48Q and CQ only.
11 Corresponds to EN 50121-3-2:2006 table 7.1 and EN 50121-4:2006 table 3.1 (radio frequency common mode).
12 Corresponds to EN 50121-4:2006 table 1.3; valid for converters with version V104 or higher.
BCD20011- G Rev AG, 12-Mar-2012
Page 19 of 26
www.power-one.com