Electromagnetic Emissions
Table 14: Emissions at Vi nom and Io nom
Model
Class accord. to EN 55011 and EN 55022
Conducted 0.15 – 30 MHz Radiated 30 – 1000 MHz
BQ
B
A
48Q /CQ
B
A
DQ
A
A
EQ
A
A
GQ
B
A
Note: Outputs lines decoupled with ferrite cores allow compliance
with class B for radiated emissions.
All conducted emissions (fig. 23) have been tested according
to IEC/EN 55022 (similar to EN 55011, much better values
than requested by EN 50121-3-2, table 3.1). The limits in fig.
23 apply to quasipeak values, which are always lower then
peak values.
In addition, the values for average must keep a limit 10 dBµV
below the limits in fig. 23 (not shown).
dBµV
80
60
PMM 8000 PLUS: Peak, conducted Vi+, Clp 2007-06-05, 15:15 h
EQ2660-7R V102, Ui=110 V, Uo=24 V Io= 4 A, decoupled load
JM021
EN 55011 B
40
20
0
0.2
0.5
1
2
5
10
20 MHz
Fig. 23c
Conducted peak disturbances at the input: EQ2320-7R V102,
Vi nom , Io nom, outputs parallel connected, decoupled load lines
Radiated emissions have been tested according to IEC/EN
55011 (similar to EN 55022), as requested in EN 50121-3-2,
table 6.1. The test is executed with horizontal and vertical
polarization. The worse result is shown in fig. 24.
dBµV
80
60
PMM 8000 PLUS: Peak, conducted Vi+, Clp 2007-06-07, 14:46 h
BQ1001-7R V104, Ui=24 V, Uo=5.1 V, Io= 16 A, decoupled load
JM019
EN 55022 B
dBµV/m
50
40
TÜV-Divina, ESVS 30:R&S, BBA 9106/UHALP 9107:Schwarzb., QP, 2009-04-21
Testdistance 10 m, BQ2660-7R V104, Ui=24 V, Uo=24 V Io= 4.4 A
EN 55011 A
40
30
< 30 dB(µV/m)
20
0
,
0.2
0.5
1
2
5
10
20 MHz
Fig. 23a
Conducted peak disturbances at the input: BQ1001-7R V104,
Vi nom, Io nom, decoupled load lines
20
10
0
30
50
100
200
500
1000 MHz
Fig. 24a
Radiated disturbances in 10 m distance: BQ2660-7R V104,
Vi nom, Io nom
dBµV
80
60
PMM 8000 PLUS: Peak, conducted Vi+, Clp 2007-06-07, 15:38 h
CQ2320-7R V104, Ui=48 V, Uo=12 V Io= 8 A, decoupled load
JM020
EN 55022 B
40
20
0
0.2
0.5
1
2
5
10
20 MHz
Fig. 23b
Conducted peak disturbances at the input: CQ2320-7R V104,
Vi nom, Io nom, outputs parallel connected, decoupled load lines
dBµV/m
50
40
30
20
TÜV-Divina, ESVS 30:R&S, BBA 9106/UHALP 9107:Schwarzb., QP, 2009-04-17
Testdistance 10 m, EQ2660-7R V104, Ui=110 V, Uo=24 V Io= 4.4 A
EN 55011 A
< 30 dB(µV/m)
10
0
30
50
100
200
500
1000 MHz
Fig. 24b
Radiated disturbances in 10 m distance: EQ2660-7R V104,
Vi nom, Io nom