English
Language : 

TDA8004T Datasheet, PDF (16/24 Pages) NXP Semiconductors – IC card interface
Philips Semiconductors
IC card interface
Product specification
TDA8004T
SYMBOL
PARAMETER
CONDITIONS
MIN. TYP. MAX. UNIT
Timing
tact
tde
t3
t5
activation sequence duration
deactivation sequence duration
start of the window for sending CLK
to the card
end of the window for sending CLK
to the card
see Fig.5
see Fig.6
see Fig.5
see Fig.5
−
180 220
µs
60
80 100
µs
−
−
130
µs
140
−
−
µs
Notes
1. To meet these specifications VCC should be decoupled to CGND using two ceramic multilayer capacitors of low ESR
with values of either 100 nF or one 100 nF and one 220 nF.
2. The transition times and duty factor definitions are shown in Fig.9; δ = (---t--1---t-+-1----t--2---)
3. PRES and CMDVCC are active LOW; RSTIN and PRES are active HIGH; for CLKDIV1 and CLKDIV2 see Table 1;
RFU1 must be tied HIGH.
handbook, full pagewidth
tr
90%
tf
90%
10%
10%
t1
t2
VCC or VDD
(VOH + VOL)/2
0
MGM178
Fig.9 Definition of output transition times.
APPLICATION INFORMATION
VDD for the TDA8004T must be the same as for the microcontroller and CLKDIV1, CLKDIV2, RSTIN, PRES, PRES,
AUX1UC, AUX2UC, I/OUC, RFU1, CMDVCC and OFF should be referenced to VDD and XTAL1 also when driven by an
external clock.
For optimum layout be sure that there is enough ground area around the TDA8004T and the connector. Place the
TDA8004T very near to the connector, ideally under the connector, and decouple VDD and VDDP properly.
Refer to AN97036 for further application information for proper implementation of the TDA8004T.
1999 Dec 30