English
Language : 

S8VS-03024 Datasheet, PDF (7/38 Pages) Omron Electronics LLC – Switch Mode Power Supply
S8VS
Power ratings
240 W
480 W
Item
Type
Standard
Maintenance
forecast monitor
Total run time
monitor
Standard
Maintenance
forecast monitor
Total run time
monitor
Efficiency
With 100-VAC input 85% typical
With 200-VAC input 88% typical
85% typical
89% typical
Voltage *1
100 to 240 VAC (allowable range: 85 to 264 VAC or 80 to 370 VDC *11) 100 to 240 VAC (allowable range: 85 to 264 VAC)
Frequency *1
50/60 Hz (47 to 63 Hz)
Current
With 100-VAC input 3.8 A max., 2.9 A typical
With 200-VAC input 2.0 A max., 1.5 A typical
7.4 A max., 5.8 A typical
3.9 A max., 2.8 A typical
Input
Power factor
Harmonic current regulation
0.9 min.
Conforms to EN61000-3-2
0.95 min.
Leakage current
With 100-VAC input 0.5 mA max.
With 200-VAC input 1.0 mA max.
Inrush current *2
With 100-VAC input 17.5 A max., 14 A typical
With 200-VAC input 35 A max., 28 A typical
Voltage adjustment range *3
−10% to 15% (with V.ADJ)
−10% to 15% (with V.ADJ)
Ripple noise voltage (at rated I/O)
140 mV max.
160 mV max.
310 mV max.
Input variation influence
0.5% max. (at 85- to 264-VAC input, 100% load)
Output
Load variation influence
(rated input voltage)
Temperature variation influence
1.5% max. (with rated input, 0 to 100% load)
0.05%/°C max.
Startup time
(at rated I/O) *2
With 100-VAC input 540 ms typical
With 200-VAC input 230 ms typical
510 ms typical
510 ms typical
460 ms typical
340 ms typical
Output hold time
(at rated I/O) *2
With 100-VAC input 64 ms typical
With 200-VAC input 64 ms typical
46 ms typical
46 ms typical
37 ms typical
41 ms typical
Overload protection *2
105% to 160% of rated load current, inverted L voltage drop, automatic reset
Overvoltage protection *2, *4
Yes
Output voltage indication *5
No
Yes (selectable) *6
No
Yes (selectable) *6
Output current indication *5
No
Yes (selectable) *7
No
Yes (selectable) *7
Peak-hold current indication *5
No
Yes (selectable) *8
No
Yes (selectable) *8
Maintenance forecast monitor indication *5 No
Yes (selectable) No
Yes (selectable) No
Maintenance forecast monitor output
No
Additional
functions Total run time monitor indication *5
No
Yes (transistor output),
30 VDC max., 50 mA No
max. *9
Yes (selectable) No
Yes (transistor
output), 30 VDC
max., 50 mA max.
No
Yes (selectable)
Total run time monitor output *5
No
Yes (transistor output),
30 VDC max., 50 mA No
max. *9
Yes (transistor output),
30 VDC max., 50 mA
max. *9
Undervoltage alarm indication *5
No
Yes (selectable)
No
Yes (selectable)
Undervoltage alarm output terminals
No
Yes (transistor output), 30 VDC max.,
50 mA max. *9
No
Yes (transistor output), 30 VDC max.,
50 mA max. *9
Parallel operation
No
Series operation
Yes for up to 2 Power Supplies (with external diode)
Operating ambient temperature
Refer to the derating curve in . (with no icing or condensation)
Storage temperature
−25 to 65°C
Operating ambient humidity
25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength
3.0 kVAC for 1 min. (between all inputs and outputs/alarm outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current for standard 240-W and 480-W
models: 30 mA, detection current for 240-W models with indication monitor: 20 mA)
500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 mA)
Insulation resistance
100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC
Vibration resistance
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in X, Y, and Z directions: 240 W
10 to 150 Hz, 0.35-mm single amplitude (3 G max.) for 80 min each in X, Y, and Z directions: 480 W
Shock resistance
150 m/s2, 3 times each in ±X, ±Y, and ±Z directions
Output indicator
Yes (color: green)
Other
EMI
Conducted
Emissions
Models with indication monitor: Conforms to EN61204-3
EN55011 Class A and based on FCC Class A, Conforms to
EN61204-3 EN55011 Class B *11
Standard models: Conforms to EN61204-3 EN55011 Group 1
Class B and based on FCC Class A
Radiated Emissions
Models with indication monitor: Conforms to EN61204-3
EN55011 Class A, Conforms to EN61204-3 EN55011 Class B
*11
Standard models: Conforms to EN61204-3 EN55011 Group 1
Class B
Conforms to EN61204-3 EN55011 Class A and based on FCC
Class A
Conforms to EN61204-3 EN55011 Class B *11
Conforms to EN61204-3 EN55011 Class A
Conforms to EN61204-3 EN55011 Class B *11
EMS
Conforms to EN61204-3 high severity levels
Approved standards *11
UL Listed: UL 508 (Listing),
UL UR: UL 60950-1 (Recognition),
cUL: CSA C22.2 No.107.1,
cUR: CSA C22.2 No. 60950-1,
EN/VDE: EN 50178 (=VDE 0160), EN 60950-1 (=VDE 0805 Teil 1)
KOSHA S Mark *10
SEMI *11
F47-0706 (200-VAC input)
Weight
1,150 g max.
1,700 g max.
Note: Refer to page 5 for notes 1 to 11.
7