S8VS-03024 Datasheet, PDF (16/38 Pages) Omron Electronics LLC – Switch Mode Power Supply
S8VS
Nomenclature
60-W Models
Standard Model
S8VS-06024
1
2
Models with Indication Monitor
S8VS-06024@
1
2
6
7
8
4
4
5
5
3
90-W/120-W Models
Standard Models
S8VS-09024/S8VS-0924S/
S8VS-12024
1
2
3
Note: The S8VS-06024A is shown above.
Models with Indication Monitor
S8VS-09024@@@/
S8VS-09024@@@S/S8VS-12024@@@
1
2
3
180-W Models
Standard Model
S8VS-18024
1
6
7
10
8
9
4
12
5
4
5
1113 3
Note: The S8VS-12024A is shown above.
Models with Indication Monitor
S8VS-18024@@@
2
1
2
6
7
10
8
9
4
5
3
240-W Models
Standard Model
S8VS-24024
1
2
12
4
5
11 13 3
Note: The S8VS-18024A is shown above.
Models with Indication Monitor
S8VS-24024@@@
1
2
6
7
10
8
9
No.
Name
Function
1
Input terminals
(L), (N)
Connect the input lines to these
terminals. *1
2
Protective Earth
terminal (PE)
Connect the ground line to this
terminal. *2
3
DC Output terminals
(−V), (+V)
Connect the load lines to these
terminals.
4
Output indicator
(DC ON: Green)
Lights while a direct current (DC)
output is ON.
5
Output voltage
adjuster (V.ADJ)
Use to adjust the voltage. *3
6
Main display (Red) *4
Indicates the measurement or set
value.
Lights up when the output voltage is
V indicated. Blinks during setup of
undervoltage alarm value.
A
Lights up during indication of output
current.
Operation
7 indicator
(Orange) *4
Apk
Lights up during indication of peak
hold current.
Lights up during indication of
maintenance forecast monitor.
Yrs Blinks during setup of maintenance
forecast monitor setting. (S8VS-
@@@24A@@)
Lights up during indication of total
kh
run time monitor. Blinks during setup
of total run time monitor. (S8VS-
@@@24B@@)
8 Mode Key *4
Use the Mode Key to change the
indicated parameter or reset the
peak hold current value.
9 Up Key *5
Use the Up Key to change to the
setting mode or to increase the set
value.
10 Down Key *5
Use the Down Key to change to the
setting mode or to decrease the set
value.
11
Undervoltage
output
terminal (DC
Low)
Output when a drop is detected in
the output voltage (voltage drop =
transistor OFF).
Maintenance
Forecast
Output when the set value for
Alarm output
maintenance is reached (transistor
outputs terminal (Yrs) OFF).
12 *5, *6 *7
Total run time
output
Output when the set value for total
terminal (kh) run time is reached (transistor OFF).
*8
13
Common
terminal
Common terminal for terminals 11
and 12.
*1. The fuse is located on the (L) side. For a DC input, connect the
positive voltage to the L terminal.
*2. This is the protective earth terminal specified in the safety
standards. Always ground this terminal.
*3. The output voltage cannot be adjusted for the
S8VS-09024@@@S.
*4. S8VS-@@@24A@@/B@@/BE@ only.
*5. S8VS-@@@24A@@/B@@ only (except the S8VS-06024@).
*6. Both sinking and sourcing outputs are available.
*7. S8VS-@@@24A@@ only (excluding S8VS-06024A).
*8. S8VS-@@@24B@@ only (excluding S8VS-06024B).
4
12
4
5
5
3
11 13 3
Note: The S8VS-24024A is shown above.
* The terminal arrangement is the same for models with screwless
terminal blocks and standard models.
16