S8VS-03024 Datasheet, PDF (17/38 Pages) Omron Electronics LLC – Switch Mode Power Supply
S8VS
480-W Models
Standard Model
S8VS-48024
1
2
Models with Indication Monitor
S8VS-48024@
1
2
4
5
3
6
7
9
10
8
16
4
15
5
3
14 13 12 11
Note: The illustration shows the S8VS-48024A model.
* The terminal arrangement is the same for models with screwless
terminal blocks and standard models.
No.
Name
Function
1
AC Input terminals
(L), (N)
Connect the input lines to these
terminals. *1
2
Protective Earth
terminal (PE)
Connect the ground line to this
terminal. *2
3
DC Output terminals
(−V), (+V)
Connect the load lines to these
terminals.
4
Output indicator
(DC ON: Green)
Lights while a direct current (DC)
output is ON.
5
Output voltage adjuster
(V.ADJ)
Use to adjust the voltage.
6
Main display (Red) *3
Indicates the measurement or set
value.
Lights up when the output voltage is
V indicated. Blinks during setup of
undervoltage alarm value.
A
Lights up during indication of output
current.
Operation
7 indicator
(Orange) *3
Apk
Lights up during indication of peak
hold current.
Lights up during indication of
maintenance forecast monitor.
Yrs Blinks during setup of maintenance
forecast monitor setting. (S8VS-
48024A)
Lights up during indication of total
kh
run time monitor. Blinks during setup
of total run time monitor. (S8VS-
48024B)
8 Mode Key *3
Use the Mode Key to change the
indicated parameter or reset the
peak hold current value.
9 Up Key *3
Use the Up Key to change to the
setting mode or to increase the set
value.
10 Down Key *3
Use the Down Key to change to the
setting mode or to decrease the set
value.
Undervoltage
11
output terminal
(DC Low)
(Emitter side) Output when a drop is detected in
the output voltage (voltage drop =
Undervoltage transistor OFF).
12
output terminal
(DC Low)
(Collector side)
Maintenance
Forecast
Output when the set value for
output terminal maintenance is reached (transistor
(Yrs) *4
OFF).
13
Alarm (Emitter side)
outputs
*3
Total run time
output terminal Output when the set value for total
(kh) *5
run time is reached (transistor OFF).
(Emitter side)
Maintenance
Forecast
Output when the set value for
output terminal maintenance is reached (transistor
(Yrs) *4
OFF).
14
(Collector side)
Total run time
output terminal Output when the set value for total
(kh) *5
run time is reached (transistor OFF).
(Collector side)
15,
16
NC (Not connected)
*1. The fuse is located on the (L) side. It is NOT user replaceable.
*2. This is the protective earth terminal specified in the safety standards.
Always ground this terminal.
*3. S8VS-48024A/B only.
*4. S8VS-48024A only.
*5. S8VS-48024B only.
17