■ Characteristics
Display range
Measurement accuracy
(at 23±5°C)
Measurement range
Input signals
Connectable sensors
Comparative output response
time (transistor output)
Linear output response time
Insulation resistance
Dielectric strength
Noise immunity
Vibration resistance
Shock resistance
Weight
Degree of
protection
Front panel
Rear case
Terminals
Memory protection
Applicable standards
EMC
−19,999 to 99,999
Functions F1, F6: ±0.006% rgd ±1 digit (for voltage pulse/open collector sensors)
Functions F2 to F5: ±0.02% rgd ±1 digit (for voltage pulse/open collector sensors)
Functions F1 to F6: 0.5 mHz to 50 kHz (for voltage pulse/open collector sensors)
No-voltage contact (30-Hz max. with ON/OFF pulse width of 15 ms min.)
Voltage pulse (50-KHz max. with ON/OFF pulse width of 9 µs min.; ON voltage: 4.5 to 30 V;
OFF voltage: −30 to 2 V; input impedance: 10 kΩ)
Open collector (50-KHz max. with ON/OFF pulse width of 9 µs min.)
ON residual voltage: 3 V max.
OFF leakage current: 1.5 mA max.
Load current:
Must have a switching capacity of 20 mA or higher.
Must be able to properly switch load currents of 5 mA or less.
Functions F1 to F6: 100 ms max. (time until the comparative output is made when there is a forced sudden
change in the input signal from 15% to 95% or 95% to 15%.)
Functions F1 to F6: 110 ms max. (time until the final analog output value is reached when there is a forced
sudden change in the input signal from 15% to 95% or 95% to 15%.)
20 MΩ min. (at 500 VDC)
2,300 VAC for 1 min between external terminals and case
100 to 240 VAC models:
±1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1 µs/100 ns)
24 VAC/VDC models:
±1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1 µs/100 ns)
Frequency: 10 to 55 Hz; Acceleration: 50 m/s2, 10 sweeps of 5 min each in X, Y, and Z directions
150 m/s2 (100 m/s2 for relay outputs) 3 times each in 3 axes, 6 directions
Approx. 300 g (Base Unit only)
Conforms to NEMA 4X for indoor use (equivalent to IP66)
IP20
IP00 + finger protection (VDE0106/100)
EEPROM (non-volatile memory)
Number of rewrites: 100,000
UL61010C-1, CSA C22.2 No. 1010.1 (evaluated by UL)
EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II
EN61326: 1997, A1: 1998, A2: 2001
EMI: EN61326+A1 industrial applications
Electromagnetic radiation interference
CISPR 11 Group 1, Class A: CISPRL16-1/-2
Terminal interference voltage
CISPR 11 Group 1, Class A: CISPRL16-1/-2
EMS: EN61326+A1 industrial applications
Electrostatic Discharge Immunity
EN61000-4-2: 4 kV (contact), 8 kV (in air)
Radiated Electromagnetic Field Immunity
EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz, 1.4 to 2 GHz)
Electrical Fast Transient/Burst Immunity
EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line)
Surge Immunity
EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line)
Conducted Disturbance Immunity
EN61000-4-6: 3 V (0.15 to 80 MHz)
Power Frequency Magnetic Immunity
EN61000-4-8: 30 A/m (50 Hz) continuous time
Voltage Dips and Interruptions Immunity
EN61000-4-11: 0.5 cycle, 0°/180°, 100% (rated voltage)
6
Rotary Pulse Indicator K3HB-R