K3HB Datasheet, PDF (13/32 Pages) Omron Electronics LLC – Digital Indicators
Operation
■ Functions (Operating Modes)
F1 to F6
These functions use the internal system clock to measure the time between pulses or the pulse ON time and then display time measurements or
a variety of other calculations.
Example: F1 Passing Speed
The time (T) between input A pulse and input B pulse
Function name
Function No.
is measured by the internal system clock. If, for
example, the system clock measures 100,000 counts
Passing speed
f1
during time T, then
Cycle
f2
Input A
T = 1 system clock count (0.5 µs) × 100,000
Time difference
f3
Time band
f4
Measuring length
f5
Interval
f6
Input B
Internal
system clock
1
T
1
T = 0.05 s
F1 (the passing speed) is calculated internally
using the formula
1
T
× 60 (m/min), and the
display, in this example, would be
1
0.05 s
× 60=
1200 (m/min).
Function
F1
Passing
speed
Operation
The reciprocal of the time (T) from input A ON to input
B ON is multiplied by 60 and displayed.
Input A
Input B
T2
TR
T1 TR
HOLD input
T3
T4
TR
Operation image (application)
Measuring workpiece passing speed between A and B
A
B
F2
Cycle
F3
Time dif-
ference
Display
1 × 60
T1
1 × 60
T2
1 × 60
T4
• Recovery time (TR) of 20 ms is required before
starting the next measurement.
æ Display unit:
ö
ç
ç
è
mm/s, m/s
m/min, km/h,
etc.
÷
÷
ø
Measures and displays input A cycle (T).
Measuring feed cycles for parts
Input A
T1
T2
T3
T4
T5
HOLD input
Display
T1
T2
T5
Measurement range: 20 ms to 3,200 s
æ Display unit: ö
ç
ç
è
ms, s, min.,
min.s.1/10 s
÷
÷
ø
Displays the time (T) from input A ON to input B ON.
Input A
Measuring workpiece passing time
between A and B
Measuring the length of a
workpiece step by changing
prescale values.
Input B
T1 TR
T2
TR
T3
TR
T4
HOLD input
Display
T1
T3
T4
Measurement range: 10 ms to 3,200 s
• Recovery time (TR) of 20 ms is required before
starting the next measurement.
æ Display unit: ö
ç
ç
è
ms, s, min.,
min.s.1/10 s
÷
÷
ø
A
B
Timer Interval Indicator K3HB-P