Features
Many I/O Variations for Discrimination, Control, and Information Applications
Digital Indicators are used in a wide variety of applications, from an electronic measurement value display or equipment/device operating status
display to a host communications interface in monitoring and control systems. OMRON provides a complete lineup for a variety of input and control
output applications to meet all your application requirements.
Relay Outputs
Transistor Outputs
H and L: SPDT
C1
H/OUT4 C2
C3
C4
L/OUT2 C5
C6
HH, H, L, and LL: SPST-NO PASS: SPDT
HH/OUT5 C1
H/OUT4 C2
COM C3
L/OUT2 C4
LL/OUT1 C5
COM C6
B1
PASS/OUT3 B2
B3
N/C B4
(CPB)
10 VDC 100 mA
(CPA)
12 VDC 80 mA
+
B5 Sensor
power
− B6 supply
NPN or PNP
HH/OUT5 C1
NPN
H/OUT4 C2
PASS/OUT3 C3
L/OUT2 C4
LL/OUT1 C5
COM C6
PNP
Communications
Output
RS-232 or RS-485
RS-232C or
RS-485
Computer
Linear Output
Voltage Output or Current Output
0 to 20 mA DC/
4 to 20 mA DC
or
0 to 5 VDC/
1 to 5 VDC/
0 to 10 VDC
DeviceNet
BCD Output
NPN Open Collector
Select a Comparative Output Pattern to
Suit the Discrimination or Control
Application
• The output pattern for comparative outputs can be selected. In
addition to high/low comparison with set values, output based on
level changes is also possible. (Use the type of output pattern
appropriate for the application.)
Comparative
set value HH
Comparative
set value H
Comparative
set value L
Comparative
set value LL
Output HH
Output H
Output PASS
Output L
Output LL
Standard Outputs
Measurement
value
Comparative
Higher
set value HH
Comparative
set value H
Comparative
Lower
set value L
Comparative
set value LL
ON
OFF Output HH
Output H
Output PASS
Output L
Output LL
Level Outputs
Measurement
value
Higher
Lower
ON
OFF
Comparative
set value HH
Comparative
set value H
Comparative
set value L
Comparative
set value LL
Output HH
Output H
Output PASS
Output L
Output LL
Zone Outputs
Measurement
value
Higher
Lower
ON
OFF
Note: The HH, H, L or LL outputs must be set in that order for the zone
outputs to output correctly.
(This is because the comparative set values and outputs for
standard and level outputs are in a 1-to-1 relationship, whereas
the meaning of zone outputs depends on the settings of all the
comparative set values.)
Lineup Includes DeviceNet Models
Enabling High-speed Data
Communications with PLCs without
Special Programming
• DeviceNet compliance enables high-speed data transmission by
allocating setting and monitoring parameters in the I/O memory of
the PLC. This capability greatly reduces labor spent in developing
communications programs.
DeviceNet
Master
Ethernet
P
H
Zero
P
H
Zero
K3HB
Digital Indicators
DeviceNet
Configurator
2
Digital Indicators K3HB Series (Pulse Input Series)