K3HB Datasheet, PDF (14/32 Pages) Omron Electronics LLC – Digital Indicators
Function
Operation
F4
Displays input A ON time (T).
Time band
Input A
T1
T2
TR
T3
TR
HOLD input
Operation image (application)
Monitoring the ON time of a printing
press
Managing the valve release
time
Communications
output
Display
T1
T3
F5
Measuring
length
Measurement range: 10 ms to 3,200 s
• Recovery time (TR) of 20 ms is required before
starting the next measurement.
æ Display unit: ö
ç
ç
è
ms, s, min.,
min.s.1/10 s
÷
÷
ø
Displays the number of input A pulses while input B is
ON.
123456
12345
Measuring workpiece length
Input A
BCD
To Programmable Controller
Input B
HOLD input
F6
Interval
Display
6
5
• Recovery time (TR) of 20 ms is required before
starting the next measurement.
æ Display unit:
ö
ç
è
mm,
cm,
m,
etc.
÷
ø
Displays the number of input A pulses from when input
B turns ON until input B turns ON again. Measurement
is made every other time input B turns ON.
Measuring slit intervals
1234
12 34
12
1
Input A
Input B
TR
TR
HOLD input
H
PASS
L
OK judgment
Display
3
4
• Recovery time (TR) of 20 ms is required before
starting the next measurement.
æ Display unit:
ö
ç
è
mm,
cm,
m,
etc.
÷
ø
INA
INB
Display
12 3
12
12
TR
TR
3
2
■ What Is Prescaling?
To make calculations using the input pulse to display the passing speed between two points, the distance between the two points and the display
unit must be set and the internally measured time multiplied by a certain coefficient. This coefficient is called the prescale value. (For information
on settings details, refer to the User's Manual.)
Time Unit Settings
Setting
Meaning
scal
Prescale value menu setting
min
Minute display
h.mm.ss
mm.ss.d
h.mm.ss display
mm.ss.d display (d = tenths of a second)
Input Type Setting
No-contact or
voltage pulse
input
Contact
NO: Voltage pulse high NC: Voltage pulse low
00
01
10
11
Note: Set to 10 or 11 when there is a large variation in the display.
The largest measurement range is 30 Hz.
14
Timer Interval Indicator K3HB-P