English
Language : 

K3HB Datasheet, PDF (26/32 Pages) Omron Electronics LLC – Digital Indicators
■ Component Names and Functions
Max./Min. status indicator
Turns ON when the maximum value or minimum
value is displayed in the RUN level.
Level/bank display
In RUN level, displays the bank if the bank function is
ON. (Turns OFF if the bank function is OFF.)
In other levels, displays the current level.
PV display
Displays PVs, maximum values,
minimum values, parameter
names, and error names.
Position meter
Displays the position of the PV
with respect to a desired scale.
Comparative output
status indicators
Display the status of comparative
outputs.
Status indicators
Display
Function
CMW
Lit when communications writing is ON
(enabled) and not lit when OFF (prohibited).
Hold
Turns ON/OFF when hold input turns
ON/OFF.
HH Max
H Min
PB
L
L
LL
CMW
Hold
HH H
T LL L
MAX/MIN
LEVEL
MODE
SHIFT
SV display
Displays SV and monitor values.
UP
HH H
T LL L
HH H
LL L
5
4
3
T
1
2
SV display status indicators
K3HB-R
Indicator
Function
Turns ON when parameters for which
T teaching can be performed are
displayed.
HH, H,
In RUN level, turn ON when the
comparative set value HH, H, L, or LL
L, LL is displayed.
K3HB-P
Indicator
Function
HH, H,
In RUN level, turn ON when the
comparative set value HH, H, L, or LL
L, LL is displayed.
K3HB-C
Indicator
Function
Turns ON when parameters for which
T teaching can be performed are
displayed.
5,
4,
3,
In RUN level, turn ON when the
comparative set value 1, 2, 3, 4, or 5 is
2, 1 displayed.
MAX/MIN Key
Used to switch the
display between the
PV, maximum value,
and minimum value and
to reset the maximum
and minimum values.
LEVEL Key
Used to switch level.
MODE Key
Used to switch the
parameters displayed.
SHIFT Key
Used to change
parameter settings.
When changing a set
value, this key is used
to move along the
digits.
UP Key
When changing a set
value, this key is used
to change the actual
value.
When a measurement
value is displayed, this
key is used to execute
or clear the forced-zero
function or to execute
teaching.
26