■ Ratings
Supply voltage
Allowable power supply voltage
range
Power consumption
(See note 1.)
Current consumption
Input
External power supply
Event inputs Hold input
(See note 2.) Reset input
Bank input
Output ratings Relay output
(depends on
the model)
Transistor output
Linear output
Display method
Main functions
Ambient operating temperature
Ambient operating humidity
Storage temperature
Altitude
Accessories
100 to 240 VAC, 24 VAC/VDC, DeviceNet power supply: 24 VDC
85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC
100 to 240 VAC: 18 VA max. (max. load)
24 VAC/DC: 11 VA/7 W max. (max. load)
DeviceNet power supply: 50 mA max. (24 VDC)
No-voltage, voltage pulse, open collector
12 VDC 10%, 80 mA (for models with external power supplies only)
NPN open collector or no-voltage contact signal
ON residual voltage: 2 V max.
ON current at 0 Ω: 4 mA max.
Max. applied voltage: 30 VDC max.
OFF leakage current: 0.1 mA max.
250 VAC, 30 VDC, 5 A (resistive load)
Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations
Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 µA max.
Linear output 0 to 20 mA DC, 4 to 20 mA:
Load: 500 Ω max, Resolution: Approx. 10,000, Output error: ±0.5% FS
Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC:
Load: 5 kΩ max, Resolution: Approx. 10,000, Output error: ±0.5% FS
(1 V or less: ±0.15 V; not output for 0 V or less)
Negative LCD (backlit LED) display
7-segment digital display (Character height: PV: 14.2 mm (green/red); SV: 4.9 mm (green))
Scaling function, measurement operation selection, output hysteresis, output OFF delay, output test, teaching, dis-
play value selection, display color selection, key protection, bank selection, display refresh period, maximum/mini-
mum hold, reset
−10 to 55°C (with no icing or condensation)
25% to 85%
−25 to 65°C (with no icing or condensation)
2,000 m max.
Watertight packing, 2 fixtures, terminal cover, unit stickers, instruction manual. DeviceNet models also include a De-
viceNet connector (Hirose HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note 3.)
Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular
attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is
recommended.
2. PNP input types are also available.
3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for
Thin Cables.
Timer Interval Indicator K3HB-P