E32DC200F Datasheet, PDF (56/67 Pages) Omron Electronics LLC – These Fibers Units can be used in a variety of applications, such as detecting the presence of workpieces and positioning.
Fiber Units with Reflective Sensors
Environment-resistant Models Heat-resistant Models
E32-D51 R35
Sensing surface
Two, 1.5 dia.
M6×0.75 (brass/nickel plating)
Width 10, thickness 2.4 (nickel-plated brass)
Washer (nickel-plated iron)
Two 2.2 dia.
4.9
Flexible Break-resistant Fluororesin coating R@ Standard
Cutting free (Cutter provided)
3.1
3 13
17
2,000
Note: The maximum allowable temperature is 150°C. The maximum
allowable temperature for continuous operation is 130°C.
E32-D81R-S R10
E32-D81R R10
Sensing surface
1.2 dia.
3
2
20
Using the E32-D81R-S
M4×0.7
M6×0.75 (SUS303)
Width 10, thickness 2.4 (SUS303)
Washer (SUS)
Fluororesin tube
Protective tube
2.2 dia.
4.5 8.5
(70)
5
A
2,000
*
5
25(B)
Using the E32-D81R
SUS303
2.2 dia.
*
6.4
29.5(B)
Note 1. The maximum allowable temperatures
for sections A and B are 200°C and
110°C, respectively. The section in-
serted into the Amplifier Unit (indicated
by *), however, must stay within the
Amplifier Unit's operating temperature
range.
2. Order the Fiber Unit based on the Amplifier
Unit. Use the E32-D81R-S if the E3X-
8 15 DA@-S, E3X-MDA@, or E3X-DAC@-S is
used. Use the E32-D81R if any other
Amplifier is used.
E32-D61-S R25
E32-D61 R25
Using the E32-D61-S
Sensing surface 1.4 dia.
M6×0.75 (SUS303)
M4×0.7
Width 10, thickness 2.4 (SUS303)
Washer (SUS)
5 dia. *2 SUS flexible tube 3.5 dia. 2.2 dia.
4.5 8.5
3
2
20
5 *3
2,000
A
*1
5
25(B)
Using the E32-D61
Hexagonal caulking
SUS316L
Note 1. The maximum allowable temperatures
for sections A and B are 350°C and
110°C, respectively. The section insert-
ed into the Amplifier Unit (indicated by
*1), however, must stay within the Ampli-
fier Unit's operating temperature range.
2. Order the Fiber Unit based on the Amplifier
8 15
Unit. Use the E32-D61-S if the E3X-DA@-S,
E3X-MDA@, or E3X-DAC@-S is used. Use
the E32-D61 if any other Amplifier is used.
*1
6.4
29.5(B)
*2. The diameter is 6 dia. if the fiber length exceeds 10 m.
*3. The diameter is 10 if the fiber length exceeds 10 m.
E32-D73-S R25
E32-D73 R25
Stainless-steel tube
Sensing surface 1.25 dia.
1 dia.
1.65 dia.
2.5 dia.
5
5
60
20
A
Using the E32-D73-S
M4×0.7 (SUS303)
Width 7, thickness 2.4 (SUS304)
Washer (SUS)
SUS flexible tube 2.8 dia.
4 dia.
2.2 dia.
10 2,000
B
*
5
25(C)
Using the E32-D73
4.5 8.5
Hexagonal caulking
SUS316L
*
6.4
29.5(C)
Note 1. The maximum allowable tempera-
tures for sections A, B, and C are
400°C, 300°C, and 110°C, respec-
tively. The section inserted into the
Amplifier Unit (indicated by *), how-
ever, must stay within the Amplifier
Unit's operating temperature range.
8 15
2. Order the Fiber Unit based on the
Amplifier Unit. Use the E32-D@-S if the
E3X-DA@-S, E3X-MDA@, or
E3XDAC@-S is used. Use the E32-D@ if
any other Amplifier is used.
Environment-resistant Models Chemical-resistant Models
E32-D12F R40
E32-D14F R40
7 dia. (fluororesin)
6 dia. (Fluororesin)
5 dia.
Two, 2.2 dia.
16
2,000
4.5
26
2,000
100
Optical axis confirmation mark (red)
Two, 2.2 dia.
100
56