English
Language : 

E32DC200F Datasheet, PDF (35/67 Pages) Omron Electronics LLC – These Fibers Units can be used in a variety of applications, such as detecting the presence of workpieces and positioning.
Accessories
Lens Units
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Type
Appearance
Dimen-
sions
page
Sensing distance (mm)
Applicable
Fiber Units
High-
resolution
mode
Standard
mode
High-
speed
mode
Super-
high-
speed
mode
Standard
object (min.
sensing
object) (mm)
*1
Features
Model
number
E32-T11L
4,000*2 3,200 2,100
840
E32-TC200 4,000*2 4,000*2 2,600 1,500
Long-dis-
tance
E32-T11R
4,000*2 3,700 2,400
60
E32-T11
4,000*2 3,600 2,300
E32-T11U
4,000*2 3,600 2,300
970
930
4 dia.
(0.1 dia.)
930
sensing;
opening
angle: 5° to E39-F1
40° (heat
resistant
E32-T81R-S 2,650 2,100 1,300
520
up to
200°C)
E32-T61-S 4,000*2 3,400 2,200
900
E32-T11L
910
800
500
180
E32-TC200
840
700
450
160
Side-view,
E32-T11R
520
400
250
100
space-sav-
60
E32-T11
820
660
430
160
3 dia.
(0.1 dia.)
ing (heat
resistant
E39-F2
E32-T11U
820
660
430
160
up to
E32-T81R-S
360
280
180
70
200°C)
E32-T61-S
600
450
300
120
E32-T11L
E32-TC200
E32-T11R
60
E32-T11
---
E32-T11U
E32-T81R-S
E32-T61-S
Long dis-
tance re-
---
flection
(heat resis-
E39-F3
tant up to
200°C)
60
E32-C42
E32-D32
Spot diameter variable in the range 0.1 to 0.6 mm at dis-
tances in the range 6 to 15 mm
Spot diameter variable in the range 0.5 to 1 mm at dis-
tances in the range 6 to 15 mm
Small spot
(variable)
E39-F3A
E32-C41 0.1-dia. spot at a distance of 7 mm
60
E32-C31 0.5-dia. spot at a distance of 7 mm
Small spot E39-F3A-5
E32-C41 0.2-dia. spot at a distance of 17 mm
60
E32-C31 0.5-dia. spot at a distance of 17 mm
Long dis-
tance,
E39-F3B
small spot
Long-dis-
60
E32-C31
E32-C41
Spot diameter of 4 mm max. at distances in the range 0 to
20 mm
tance
sensing,
parallel
E39-F3C
light
*1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*2. The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
35