E32DC200F Datasheet, PDF (17/67 Pages) Omron Electronics LLC – These Fibers Units can be used in a variety of applications, such as detecting the presence of workpieces and positioning.
ì¡í²ÅEÉAÉvÉäÉPÅ[ÉVÉáÉì
Application-corresponding Models
Glass-substrate Alignment
• There is little variation of detection position within the
detection range (±0.1 mm max.)
• The different model variations can handle a variety of
sensing distances and temperature conditions.
■ Engineering Data (E32-A07/A08/L16-N)
Detection-Position Characteristic (Typical Examples)
E32-A07
25
Sensing object: Raw glass
(t = 0.7 mm, rounded edge)
X
Y
20
15
E32-L16-N
■ Overview of Model Variations
Type
Features
0 to 15 mm, wide-range sensing
10
E32-A08
5
E32-L16-N
0
2.5 3.0 3.5 4.5 5.0 6.0
Shape, sensing distance (mm)* Model number
0 to 15 E32-L16-N
Long-distance sensing
10 to 20 E32-A08
15 to 25
E32-A07E1
E32-A07E2
Heat-resistant up to 300°C
5 to 18 E32-L66
*The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
Glass-substrate Mapping
• These models can reliably detect thin glass-substrate
end faces (t = 0.5 mm, beveled edge).
• Using a large-diameter lens makes it possible to cope
with tilting of the glass substrates.
■ Engineering Data (E32-A09)
Digital Light-intensity Value vs Sensing Distance
(Typical Examples)
300
250
Beveled
200
edge
Rounded
150
edge
100
50
0
0 10 20 30 40 50 60 70
Sensing distance, X (mm)
Angle Characteristics in Left and Right Directions
(Typical Example)
100
75
50
25
0
−10 −8 −6 −4 −2 0 2 4 6 8 10
Angle, θ (o)
Sensing object: Raw glass
(t = 0.5 mm, beveled/rounded edge)
X mm
Sensing object: Raw glass
(t = 0.5 mm, rounded edge)
25 mm
+θ
Emission side
E32-A09
−θ
Reception side
■ Overview of Model Variations
Type
Features
Large-diameter lens ensures re-
sistance to tilting
Heat-resistant up to 150°C
Shape, sensing distance (mm)*
15 to 38 (center: 25)
Model number
E32-A09
E32-A09H
Heat-resistant up to 300°C
20 to 30 (center: 25) E32-A09H2
*The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).