PC8374L Datasheet, PDF (179/239 Pages) National Semiconductor (TI) – SensorPathTM SuperI/O with Glue Functions
Winbond Electronics Corp. Advanced PC Product Center
8.0 Health Management (HM) (Continued)
Bit
Description
7-6 GAIN (Gain Correction). Same as GAIN in Temperature Zone1 Gain and Offset Correction register, but for
Temperature Zone2.
5-4 Reserved.
3-0 OFFSET (Offset Correction). Same as OFFSET in Temperature Zone1 Gain and Offset Correction register, but
for Temperature Zone2.
8.5.58 Temperature Zone3 Gain and Offset Correction
Temperature gain and offset correction for Zone3 temperature monitoring.
Location: 7Fh
Type: R/W (Becomes read-only when LOCK bit in the Configuration register is set.)
Bit
7
6
5
4
3
2
1
0
Name
GAIN
Reserved
OFFSET
Reset
0
0
0
0
0
0
0
0
Bit
Description
7-6 GAIN (Gain Correction). Same as GAIN in Temperature Zone1 Gain and Offset Correction register, but for
Temperature Zone3.
5-4 Reserved.
3-0 OFFSET (Offset Correction). Same as OFFSET in Temperature Zone1 Gain and Offset Correction register, but
for Temperature Zone3.
8.5.59 Enhanced Thermal Control Register
Location: 80h
Type: R/W (Becomes read-only when LOCK bit in the Configuration register is set.)
Bit
7
6
5
4
3
2
Name
Reserved
Reset
0
0
0
0
0
0
1
0
ETC_EN
0
1
Bit
Description
7-1 Reserved
0 ETC_EN. When set to 1, the ETC internal signal is asserted if one of the following conditions is true:
• The temperature data value in Temperature Zone1 is higher than the critical limit set in the Temperature Crit-
ical Limit Zone1 register.
• A communication error with Device 1 (LM96011 or LM96010 or LM96012) occurs.
• A major SensorPath Bus failure is detected.
An asserted ETC signal turns off the Main power supply (via the Glue module). The resulting ETC signal is
disabled when the VDD3 power is off and remains disabled until both of the following conditions are met:
• The delay time (182 ms) for enabling VDD channels (see Section 8.5.55 on page 177) after VDD3 power is
turned on, has elapsed.
• The temperature data in Temperature Zone1 was updated with a new value by the LMxx Sensor device
If the temperature data from Device 1 (LM96011 or LM96010 or LM96012) is not updated for 728 ms after VDD3
power is on (see “Time-Out Function” on page 133), the HM assumes a communication error with the LMxx Sensor
device occurred and asserts ETC.
0: Disable assertion of ETC
1: Enable assertion of ETC (default)
Revision 1.1
179
www.national.com