ARRAY WRITE
[01 1110] [1][0] [0][0][0][0] //*Array position 1, Return Configuration Information *//
[01 1110] [0][0] [0][0][0][0] //*Array position 0, Return Configuration Information *//
20028711
DEVICE 0 READ PROGRAMMING SEQUENCE
SCLK
Number
6
18
36
48
60
74
Event Description
Device 0 (R=0, C=0) detects “READ” frame of first Control Word.
Device 0 (R=0,C=0) sees Row = 1, Column = 0 of first Control Word. The Row address of the first Control Word is
decremented by 1 (Row Address = 0) and sent out RSO.
Device 0 (R=0,C=0) detects "READ" frame of second Control Word.
Device 0 (R=0,C=0) sees Row = 0, Column = 0 of second Control Word. This is a valid configuration read address, Device
0 prepares to transmit configuration information. The Row address of the last Control Word is decremented by 1 (Row
Address = 3F) and sent out RSO.
Device 0 (R=0,C=0) has transmitted configuration information.
Finished transmitting configuration information at Array Output (RSO of Device 1).
DEVICE 1 READ PROGRAMMING SEQUENCE
SCLK
Number
13
25
37
Event Description
Device 1 (R=1, C=0) detects “READ” frame of first Control Word.
Device 1 (R=1,C=0) sees Row = 0, Column = 0 of first Control Word. This is a valid configuration read address, Device
1 prepares to transmit configuration information. The Row address of the last Control Word is decremented by 1 (Row
Address = 3F) and sent out RSO.
Device 1 (R=1,C=0) has transmitted configuration information at Array Output (RSO of Device 1).