System Management Bus (SMBus)
and Configuration Registers
The System Management Bus interface is compatible to SM-
Bus 2.0 physical layer specification. ENSMB must be pulled
high to enable SMBus mode and allow access to the config-
uration registers.
The DS64BR401 has the AD[3:0] inputs in SMBus mode.
These pins are the user set SMBus slave address inputs. The
AD[3:0] pins have internal pull-down. When left floating or
pulled low the AD[3:0] = 0000'b, the device default address
byte is A0'h. Based on the SMBus 2.0 specification, the
DS64BR401 has a 7-bit slave address of 1010000'b. The LSB
is set to 0'b (for a WRITE), thus the 8-bit value is 1010 0000'b
or A0'h. The device address byte can be set with the use of
the AD[3:0] inputs. Below are some examples.
AD[3:0] = 0001'b, the device address byte is A2'h
AD[3:0] = 0010'b, the device address byte is A4'h
AD[3:0] = 0100'b, the device address byte is A8'h
AD[3:0] = 1000'b, the device address byte is B0'h
The SDC and SDA pins are 3.3V LVCMOS signaling and in-
clude high-Z internal pull up resistors. External low
impedance pull up resistors maybe required depending upon
SMBus loading and speed. Note, these pins are not 5V tol-
erant.
TRANSFER OF DATA VIA THE SMBUS
During normal operation the data on SDA must be stable dur-
ing the time when SDC is High.
There are three unique states for the SMBus:
START: A High-to-Low transition on SDA while SDC is High
indicates a message START condition.
STOP: A Low-to-High transition on SDA while SDC is High
indicates a message STOP condition.
IDLE: If SDC and SDA are both High for a time exceeding
tBUF from the last detected STOP condition or if they are High
for a total exceeding the maximum specification for tHIGH then
the bus will transfer to the IDLE state.
SMBUS TRANSACTIONS
The device supports WRITE and READ transactions. See
Register Description table for register address, type (Read/
Write, Read Only), default value and function information.
WRITING A REGISTER
To write a register, the following protocol is used (see SMBus
2.0 specification).
1. The Host drives a START condition, the 7-bit SMBus
address, and a “0” indicating a WRITE.
2. The Device (Slave) drives the ACK bit (“0”).
3. The Host drives the 8-bit Register Address.
4. The Device drives an ACK bit (“0”).
5. The Host drive the 8-bit data byte.
6. The Device drives an ACK bit (“0”).
7. The Host drives a STOP condition.
The WRITE transaction is completed, the bus goes IDLE and
communication with other SMBus devices may now occur.
READING A REGISTER
To read a register, the following protocol is used (see SMBus
2.0 specification).
1. The Host drives a START condition, the 7-bit SMBus
address, and a “0” indicating a WRITE.
2. The Device (Slave) drives the ACK bit (“0”).
3. The Host drives the 8-bit Register Address.
4. The Device drives an ACK bit (“0”).
5. The Host drives a START condition.
6. The Host drives the 7-bit SMBus Address, and a “1”
indicating a READ.
7. The Device drives an ACK bit “0”.
8. The Device drives the 8-bit data value (register contents).
9. The Host drives a NACK bit “1”indicating end of the
READ transfer.
10. The Host drives a STOP condition.
The READ transaction is completed, the bus goes IDLE and
communication with other SMBus devices may now occur.
RECOMMENDED SMBUS REGISTER SETTINGS
When SMBus mode is enabled (ENSMB = 1), the default reg-
ister settings are not configured to an appropriate level. Below
is the recommended settings to configure the EQ, VOD and
DE to a medium level that supports interconnect length of 20
inches FR4 trace or 3 to 5 meters of cable length. Please refer
to Table 1, Table 2, Table 5 for additional information and
recommended settings.
1. Reset the SMBus registers to default values:
Write 01'h to address 0x00.
2. Set equalization to external pin level EQ[1:0] = 00 (~9 dB
at 3 GHz) for all channels (CH0–CH7):
Write 30'h to address 0x0F, 0x16, 0x1D, 0x24, 0x2C,
0x33, 0x3A, 0x41.
3. Set VOD = 1.0V for all channels (CH0–CH7):
Write 0F'h to address 0x10, 0x17, 0x1E, 0x25, 0x2D,
0x34, 0x3B, 0x42.
4. Set de-emphasis to -6 dB enhance for all channels
(CH0–CH7):
Write 88'h to address 0x11, 0x18, 0x1F, 0x26, 0x2E,
0x35, 0x3C, 0x43.
5. Block the device from resetting to default values:
Write 02'h to address 0x00.
IDLE AND RATE DETECTION TO EXTERNAL PINS
The functions of IDLE and RATE detection to external pins for
monitoring can be supported in SMBus mode. The external
GPIO pins of 19, 20, 46 and 47 will be changed and they will
serve as outputs for IDLE and RATE detect signals.
The following external pins should be set to auto detection:
RATE = F (FLOAT) – auto RATE detect enabled
TXIDLEA/B = F (FLOAT) – auto IDLE detect enabled
There are 4 GPIO pins that can be configured as outputs with
reg_4E[0].
To disable the external SMBus address pins, so pin 46 and
47 can be used as outputs:
Write 01'h to address 0x4E.
Care must be taken to ensure that only the desired status
block is enabled and attached to the external pin as the status
blocks can be OR’ed together internally. Register bits reg_47
[5:4] and bits reg_4C[7:6] are used to enable each of the sta-
tus block outputs to the external pins. The channel status
blocks can be internally OR’ed together to monitor more than
one channel at a time. This allows more information to be
presented on the status outputs and later if desired, a diag-
nosis of the channel identity can be made with additional
SMBus writes to register bits reg_47[5:4] and bits reg_4C
[7:6].