Electrical Characteristics — Serial Management Bus Interface
Over recommended operating supply and temperature ranges unless other specified.
Symbol
Parameter
Conditions
Min
Typ
SERIAL BUS INTERFACE DC SPECIFICATIONS
VOL
Data (SDA) Low Level Output
IOL = 3mA
Voltage
VIL
Data (SDA), Clock (SCL) Input
Low Voltage
VIH
Data (SDA), Clock (SCL) Input
2.1
High Voltage
IPULLUP
Current Through Pull-Up Resistor High Power Specification
or Current Source
4
VDD
ILEAK-Bus
ILEAK-Pin
CI
RTERM
Nominal Bus Voltage
Input Leakage Per Bus Segment (Note 8)
Input Leakage Per Device Pin
Capacitance for SDA and SDC (Notes 8, 9)
External Termination Resistance VDD3.3,
pull to VDD = 2.5V ± 5% OR 3.3V ± (Notes 8, 9, 10)
10%
VDD2.5,
(Notes 8, 9, 10)
2.375
-200
-15
2000
1000
SERIAL BUS INTERFACE TIMING SPECIFICATIONS. See Figure 4
FSMB
Bus Operating Frequency
(Note 11)
10
TBUF
Bus Free Time Between Stop and
Start Condition
4.7
THD:STA
Hold time after (Repeated) Start At IPULLUP, Max
Condition. After this period, the first
4.0
clock is generated.
TSU:STA
Repeated Start Condition Setup
Time
4.7
TSU:STO Stop Condition Setup Time
4.0
THD:DAT Data Hold Time
300
TSU:DAT
Data Setup Time
250
TTIMEOUT
Detect Clock Low Timeout
(Note 11)
25
TLOW
Clock Low Period
4.7
THIGH
Clock High Period
(Note 11)
4.0
TLOW:SEXT Cumulative Clock Low Extend
Time (Slave Device)
(Note 11)
tF
Clock/Data Fall Time
(Note 11)
tR
Clock/Data Rise Time
(Note 11)
tPOR
Time in which a device must be (Note 11)
operational after power-on reset
Max
0.4
0.8
3.6
3.6
+200
10
100
35
50
2
300
1000
500
Units
V
V
V
mA
V
µA
µA
pF
Ω
Ω
kHz
µs
µs
µs
µs
ns
ns
ms
µs
µs
ms
ns
ns
ms
Note 8: Recommended value. Parameter not tested in production.
Note 9: Recommended maximum capacitance load per bus segment is 400pF.
Note 10: Maximum termination voltage should be identical to the device supply voltage.
Note 11: Compliant to SMBus 2.0 physical layer specification. See System Management Bus (SMBus) Specification Version 2.0, section 3.1.1 SMBus common
AC specifications for details.
www.national.com
10