A.1.6 ESD Protection and Latch-up Immunity
All ESD testing is in conformity with CDF-AEC-Q100 Stress test qualification for Automotive Grade
Integrated Circuits. During the device qualification ESD stresses were performed for the Human Body
Model (HBM), the Machine Model (MM) and the Charge Device Model.
A device will be defined as a failure if after exposure to ESD pulses the device no longer meets the device
specification. Complete DC parametric and functional testing is performed per the applicable device
specification at room temperature followed by hot temperature, unless specified otherwise in the device
specification.
Table A-2 ESD and Latch-up Test Conditions
Model
Human Body
Machine
Latch-up
Description
Series Resistance
Storage Capacitance
Number of Pulse per pin
positive
negative
Series Resistance
Storage Capacitance
Number of Pulse per pin
positive
negative
Minimum input voltage limit
Maximum input voltage limit
Symbol
R1
C
-
R1
C
-
Value
1500
100
-
1
1
0
200
-
3
3
-2.5
7.5
Unit
Ohm
pF
Ohm
pF
V
V
Table A-3 ESD and Latch-Up Protection Characteristics
Num C
Rating
1 T Human Body Model (HBM)
2 T Machine Model (MM)
3 T Charge Device Model (CDM)
Latch-up Current at TA = 125°C
4 T positive
negative
Latch-up Current at TA = 27°C
5 T positive
negative
Symbol
VHBM
VMM
VCDM
ILAT
ILAT
Min
2000
200
500
+100
-100
+200
-200
Max
-
-
-
-
-
Unit
V
V
V
mA
mA
A.1.7 Operating Conditions
This chapter describes the operating conditions of the device. Unless otherwise noted those conditions
apply to all the following data.
88