6.3.3 Strain Relief
Molex strongly recommends the use of a crimp barrel or ferrule over the wire bundle
(including ground or drain wire) that also captures the cable jacket and tension member, if used. This will uniformly distribute
mechanical loads through the wire bundle and provide mechanical support to the cable jacket and tension member.
Figure 9.
Crimp barrel installed
6.3.4 Final Over-Molding
The final PVC over-mold may be injection-molded to completely cover the prepared cable assembly to provide an esthetically
pleasing finished product. Please see Section 6.4.1 for a discussion of design best practices for the over-mold.
Figure 10.
Finished over-mold (shown transparent)