5.3. Telegram Codes
Sync Bit
Each telegram starts with the Sync Bit. This logical 0
pulse defines the exact timing for tp0.
Command Bits (COM)
The Command code contains 3 bits and is a binary
number. Table 5–2 shows the available commands and
the corresponding codes for the HAL 800.
Command Parity Bit (CP)
This parity bit is 1, if the number of zeros within the 3
Command Bits is uneven. The parity bit is 0, if the
number of zeros is even.
Address parity bit (AP)
This parity bit is 1, if the number of zeros within the 4
Address bits is uneven. The parity bit is 0, if the num-
ber of zeros is even.
Data Bits (DAT)
The 14 Data Bits contain the register information.
The registers use different number formats for the Data
Bits. These formats are explained in Section 5.4.
In the Write command the last bits are valid. If for
example the TC register (6 bits) is written, only the last
6 bits are valid.
In the Read command the first bits are valid. If for
example the TC register (6 bits) is read, only the first 6
bits are valid.
Address Bits (ADR)
The Address code contains 4 bits and is a binary num-
ber. Table 5–3 shows the available addresses for the
HAL 800 registers.
Data Parity Bit (DP)
This parity bit is 1, if the number of zeros within the
binary number is even. The parity bit is 0, if the number
of zeros is uneven.
Table 5–2: Available Commands
Command
Code Explanation
READ
2
read a register
WRITE
3
write a register
PROM
4
program all nonvolatile registers (except the lock bits)
ERASE
5
erase all nonvolatile registers (except the lock bits)
LOCKI
6
lock Micronas lockable register
LOCK
7
lock the whole device and switch permanently to the analog-mode
Please note:
The Micronas lock bit (LOCKI) has already been set during production and cannot be reset.
Micronas