English
Language : 

HAL800 Datasheet, PDF (12/24 Pages) Micronas – Programmable Linear Hall Effect Sensor
HAL 800
3.4. Absolute Maximum Ratings
Symbol
Parameter
Pin No. Min.
Max.
VDD
VDD
−IDD
IZ
VOUT
Supply Voltage
Supply Voltage
Reverse Supply Current
Current through Protection Device
Output Voltage
1
1
1
1 or 3
3
−8.5
−14.41) 2)
−
−3004)
−56)
−56)
8.5
14.41) 2)
501)
3004)
8.53)
14.43) 2)
VOUT − VDD Excess of Output Voltage
3,1
2
over Supply Voltage
IOUT
Continuous Output Current
3
−10
10
tSh
Output Short Circuit Duration
3
−
10
TS
Storage Temperature Range
TJ
Junction Temperature Range
−65
150
−40
1705)
−40
150
1)
2)
3)
4)
as
t<
as
t<
long as TJmax is not
10 minutes (VDDmin
long as TJmax is not
2 ms
exceeded
= −15 V for t < 1min, VDDmax = 16 V
exceeded, output is not protected to
for t < 1min)
external 14 V-line
(or
to
−14
V)
5) t < 1000h
6) internal protection resistor = 100 Ω
Unit
V
V
mA
mA
V
V
mA
min
°C
°C
°C
Stresses beyond those listed in the “Absolute Maximum Ratings” may cause permanent damage to the device. This
is a stress rating only. Functional operation of the device at these or any other conditions beyond those indicated in
the “Recommended Operating Conditions/Characteristics” of this specification is not implied. Exposure to absolute
maximum ratings conditions for extended periods may affect device reliability.
3.5. Recommended Operating Conditions
Symbol
VDD
IOUT
RL
CL
Parameter
Supply Voltage
Continuous Output Current
Load Resistor
Load Capacitance
Pin No.
1
3
3
3
Min.
4.5
−1
4.5
0.33
Typ.
5
−
−
10
Max.
Unit
5.5
V
1
mA
−
kΩ
1000
nF
12
Micronas