English
Language : 

RV-8523 Datasheet, PDF (41/57 Pages) MICORO CRYSTAL SWITZERLAND – Real Time Clock
Micro Crystal
Real Time Clock / Calendar Module
Example of shortening the INT_1 pulse by clearing the CTAF flag:
RV-8523
The timing shown for clearing bit CTAF is also valid for the non-pulsed interrupt mode, that is, when TAM set
logic 0, where the INT_1 pulse may be shortened by setting CTAIE logic 0.
1) Indicates normal duration of INT_1 pulse.
9.10. STOP BIT FUNCTION
The STOP bit function allows the accurate starting of the time circuits. The STOP bit function causes the upper part
of the prescaler (F2 to F14) to be held in reset and thus no 1 Hz ticks are generated. The time circuits can then be
set and do not increment until the STOP bit is released (see figure below).
STOP bit:
STOP does not affect the output of 32.768 kHz, 16.384 kHz or 8.192 kHz (see section 8.6.1.).
41/57