English
Language : 

TH8062 Datasheet, PDF (7/38 Pages) Melexis Microelectronic Systems – Voltage Regulator with LIN Transceiver
TH8062
Voltage Regulator with LIN Transceiver
Parameter
Reset threshold – low voltage reset
Vres Hysteresis
VRESHYS = |VRES(ON) – VRES(OFF)|
Master reset threshold
Input voltage low
Input voltage high
Hysteresis
Pull-down resistor EN low
Pull-down current EN high
Output voltage low
Pull-up current
Thermal shutdown
Thermal recovery
Symbol
Condition
VRES(OFF) VCC ramp down, t > trr
VRESHYS
VMRES
Enable Input EN
VENL
VENH
VENHYS
RpdENL
IpdENH
0V ≤ VEN ≤ 0.8V
VEN ≥ VENH
Output RESET
VOL1_RESET IOUT = 1 mA, VSUP ≥ 6 V
Ipu
Thermal Protection
TJSHD
TJREC
Min
Typ
Max Unit T[1]
4.4
4.65
4.8 V A
150 mV C
3.0
3.15
3.3 V D
-0.3
0.8 V B
2.0
VSUP +0.3 V B
50
300 mV C
14
25
36 kΩ A
0.5
2
10 µA A
0.8 V A
-500
-375
-250 μA A
155
180 °C D
126
°C D
[1] A = 100% serial test, B = Operating parameter, C = Only used for data characterization (cpk), D = Value guaranteed by design
[2] The nominal VCC voltage is measured at VSUP =12V. If the VCC voltage is 100mV below its nominal value then the voltage drop is
VD = VSUP – VCC.
TH8062 – Datasheet
3901008062
Page 7 of 38
March 2006
Rev 002