English
Language : 

TH8062 Datasheet, PDF (23/38 Pages) Melexis Microelectronic Systems – Voltage Regulator with LIN Transceiver
TH8062
Voltage Regulator with LIN Transceiver
If the application doesn’t need the wake up capability of the TH8062 a direct connection EN to VSUP is
possible. In this case the TH8062 operates in permanent normal mode. Also possible is the external (outside
of the module) control of the EN line via a VBAT signal. If this is a direct VBAT signal an external reverse
battery protection has to be added to the circuitry.
VBAT
LIN
TH8062
Cload
VSUP
VCC
CIN
EN
10k
RESET
GND
TxD
BUS
RxD
180p
MCU
+5V
Figure 15 - Permanent normal mode
TH8062 – Datasheet
3901008062
Page 23 of 38
March 2006