MLX80004 Datasheet, PDF (14/38 Pages) Melexis Microelectronic Systems – Enhanced Universal Dual/Quad LIN Transceiver | |||
|
◁ |
MLX80002/MLX80004
Enhanced Universal Dual/Quad LIN Transceiver
Datasheet
As shown in Figure 4, both worst case duty cycles can be calculated as follows :
Dwc1 = tBUS_rec(min) / (2 tBit )
Dwc2 = tBUS_rec(max) / (2 tBit )
Thresholds for duty cycle calculation for the plug & play specification in accordance to LIN2.0 / SAE J2602:
Baud rate
TBIT
Dwc1
Dwc2
THREC(MAX)
THDOM(MAX)
THREC(MIN)
THDOM(MIN)
20kBd
50µs
D1
D2
0.744 Ã VS_TX
0.581 Ã VS_TX
0.422 Ã VS_TX
0.284 Ã VS_TX
10.4kBd
96µs
D3
D4
0.778 Ã VS_TX
0.616 Ã VS_TX
0.389 Ã VS_TX
0.251 Ã VS_TX
Table 6: Data Transmission Rates
Revision 021 â Sept 2016
Page 14 of 38
|
▷ |