English
Language : 

MAX15569 Datasheet, PDF (31/41 Pages) Maxim Integrated Products – 2-Phase/1-Phase QuickTune-PWM Controller with Serial I2C Interface
MAX15569
2-Phase/1-Phase QuickTune-PWM Controller with
Serial I2C Interface
Slew-Rate Configuration (0x06h)
The content of the SRREG register determines the slew
rate at both initial startup and dynamic output-voltage
transition. There are 52 possibilities of selectable slew
rates (4.5mV/µs to 44mV/µs) that cover the initial startup
(soft-start) and dynamic output-voltage transition with
different slew rates in one setting. See Table 8 for bit
descriptions and Table 9 for slew-rate selections.
Table 9. Slew-Rate Selections (Register 0x06h)
D7 D6 D5 D4 D3 D2 D1 D0
X
X
0
0
0
0
0
0
X
X
0
0
0
0
0
1
X
X
0
0
0
0
1
0
X
X
0
0
0
0
1
1
X
X
0
0
0
1
0
0
X
X
0
0
0
1
0
1
X
X
0
0
0
1
1
0
X
X
0
0
0
1
1
1
X
X
0
0
1
0
0
0
X
X
0
0
1
0
0
1
X
X
0
0
1
0
1
X
X
X
0
0
1
1
0
X
X
X
0
0
1
1
1
0
X
X
0
1
0
0
0
0
X
X
0
1
0
0
0
1
X
X
0
1
0
0
1
0
X
X
0
1
0
0
1
1
X
X
0
1
0
1
0
0
X
X
0
1
0
1
0
1
X
X
0
1
0
1
1
0
X
X
0
1
0
1
1
1
X
X
0
1
1
0
0
0
X
X
0
1
1
0
0
1
X
X
0
1
1
0
X
X
X
X
0
1
1
1
1
0
X
X
1
0
0
0
0
0
X
X
1
0
0
0
0
1
X
X
1
0
0
0
1
0
X
X
1
0
0
0
1
1
X
X
1
0
0
1
0
0
X
X
1
0
0
1
0
1
SOFT-START SLEW RATE
(mV/µs)
18
9
4.5
9
4.5*
36
18
9
4.5
4.5
4.5
4.5
4.5
22
11
5.5
11
5.5
44
22
11
5.5
5.5
5.5
5.5
14
7
3.5
7
3.5
28
REGULAR SLEW RATE
(mV/µs)
18
18
18
9
9*
36
36
36
36
4.5
9
9
9
22
22
22
11
11
44
44
44
44
5.5
11
11
14
14
14
7
7
28
www.maximintegrated.com
Maxim Integrated │  31