English
Language : 

MAX16031 Datasheet, PDF (3/42 Pages) Maxim Integrated Products – EEPROM-Based System Monitors with Nonvolatile Fault Memory
EEPROM-Based System Monitors
with Nonvolatile Fault Memory
ABSOLUTE MAXIMUM RATINGS
VCC to GND ............................................................-0.3V to +15V
IN_, FAULT_, SCL, SDA, OVERT to GND.................-0.3V to +6V
A0, A1, TCK, TMS, TDI to GND ................................-0.3V to +6V
OVERC, RESET, GPIO_, ALERT to GND..................-0.3V to +6V
RBP, ABP, DBP to GND ...-0.3V to lower of (6V and VCC + 0.3V)
TDO, DXP1, DXP2 to GND..........................-0.3V to VDBP + 0.3V
CS+, CS- to GND ...................................................-0.3V to +30V
(CS+ - CS-) ............................................................................±5V
DXN1, DXN2 to GND.............................................-0.3V to +0.8V
SDA, ALERT Current ...........................................-1mA to +50mA
DXN1, DXN2 Current ............................................................1mA
Input/Output Current
(all except DXN1, DXN2, SDA, and ALERT) ..................20mA
Continuous Power Dissipation (TA = +70°C)
48-Pin, 7mm x 7mm TQFN
(derate 27.8mW/°C above +70°C) ........................2222.2mW
Operating Temperature Range ...........................-40°C to +85°C
Junction Temperature .....................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+250°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VCC = 2.9V to 14V, TA = -40°C to +85°C, unless otherwise specified. Typical values are at VCC = 3.3V, TA = +25°C.) (Note 1)
PARAMETER
Operating Voltage Range
Undervoltage Lockout
Undervoltage Lockout Hysteresis
Supply Current
ADC DC ACCURACY
Resolution
Total Unadjusted Error
Integral Nonlinearity
Differential Nonlinearity
ADC Total Monitoring Cycle Time
SYMBOL
CONDITIONS
VCC
VUVLO
Minimum voltage at VCC
to access the digital interfaces
VUVLOHYS
ICC
Static (EEPROM not accessed)
TA = -40°C to +85°C
tCYCLE
Eight supply inputs, three temperatures,
and current sense
MIN TYP MAX UNITS
2.90
14.00
V
2.8
V
100
mV
3
5
mA
10
Bits
0.9 % FSR
1
LSB
1
LSB
80
100
µs
Register map bit set to 00
(LSB = 5.46mV)
5.6
ADC IN_ Voltage Ranges
Register map bit set to 01
(LSB = 2.73mV)
2.8
V
Reference Voltage
IN_ ANALOG INPUT
VRBP
Register map bit set to 10
(LSB = 1.36mV)
1.4
1.306 1.4 1.414
V
Absolute Input Voltage Range
(Referenced to GND)
Input Impedance
0
5.6
V
30
50
80
kΩ
_______________________________________________________________________________________ 3