English
Language : 

MAX16031 Datasheet, PDF (11/42 Pages) Maxim Integrated Products – EEPROM-Based System Monitors with Nonvolatile Fault Memory
EEPROM-Based System Monitors
with Nonvolatile Fault Memory
Pin Description (continued)
PIN
MAX16031 MAX16032
21
21
22
23
24
25
26
27
28
29
33
34
36
37, 38
41
42
43
44
45
46
48
22
—
24
25
26
27
28
29
33
34
36
37, 38
41
42
—
—
45
46
48
—
—
NAME
FUNCTION
ALERT
SMBus Alert Open-Drain Output. ALERT follows the SMBALERT# signal functionality
described in Appendix A of the SMBus 2.0 Specification. ALERT asserts when the device
detects a fault, thereby interrupting the host processor to query which device on the serial
bus detected faults.
OVERT Overtemperature, Open-Drain Output. OVERT asserts when an overtemperature condition is
detected.
OVERC Overcurrent, Open-Drain Output. OVERC asserts when the primary overcurrent threshold is
exceeded.
FAULT2
FAULT1
RESET
Configurable Open-Drain Fault Output 2
Configurable Open-Drain Fault Output 1
Configurable Open-Drain Reset Output
TMS JTAG Test Mode Select Input. Internally pulled up to VDBP with a 10kΩ resistor.
TCK JTAG Test Clock Input
TDI JTAG Test Data Input. Internally pulled up to VDBP with a 10kΩ resistor.
TDO JTAG Test Data Output
DBP
Internal Digital Voltage Regulator Output. Connect a 1µF bypass capacitor from DBP to
GND. Do not use DBP to power external circuitry.
ABP
VCC
CS-
CS+
DXN2
DXP2
DXN1
DXP1
IN1
Internal Analog Voltage Regulator Output. Connect a 1µF bypass capacitor from ABP to
GND. Do not use ABP to power external circuitry.
Device Power Supply. Bypass VCC to GND with a 1µF capacitor.
Current-Sense Negative Input. Must be biased between 3V to 28V for proper operation.
Current-Sense Positive Input. Must be biased between 3V to 28V for proper operation.
Remote Diode 2 Negative Input. If remote sensing is not used, connect DXP2 to DXN2.
Remote Diode 2 Positive Input. If remote sensing is not used, connect DXP2 to DXN2.
Remote Diode 1 Negative Input. If remote sensing is not used, connect DXP1 to DXN1.
Remote Diode 1 Positive Input. If remote sensing is not used, connect DXP1 to DXN1.
Supply Monitor Input 1. IN1 is internally sampled by the ADC. It is configurable for unipolar/
bipolar and single-ended/pseudo-differential. In pseudo-differential mode, IN1 and IN2 form
the + and - of the differential pair. Each input must stay within the specified ADC IN_ voltage
range.
EP
Exposed Paddle. Connect EP to ground. EP is internally connected to GND. Do not use as
the main ground connection.
______________________________________________________________________________________ 11