Table 10. Fault Masks
REGISTER
ADDRESS
54h
55h
56h
57h
EEPROM
MEMORY
ADDRESS
D4h
D5h
D6h
D7h
BIT
RANGE
DESCRIPTION
[0]
[1]
[2]
[3]
[7:4]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
1 = Short-circuit detection at remote temperature sensor 1 is masked.
1 = Open-circuit detection at remote temperature sensor 1 is masked.
1 = Short-circuit detection at remote temperature sensor 2 is masked.
1 = Open-circuit detection at remote temperature sensor 2 is masked.
Not used.
1 = IN1 primary overvoltage and undervoltage faults are masked.
1 = IN2 primary overvoltage and undervoltage faults are masked.
1 = IN3 primary overvoltage and undervoltage faults are masked.
1 = IN4 primary overvoltage and undervoltage faults are masked.
1 = IN5 primary overvoltage and undervoltage faults are masked.
1 = IN6 primary overvoltage and undervoltage faults are masked.
1 = IN7 primary overvoltage and undervoltage faults are masked.
1 = IN8 primary overvoltage and undervoltage faults are masked.
1 = IN1 secondary overvoltage and undervoltage faults are masked.
1 = IN2 secondary overvoltage and undervoltage faults are masked.
1 = IN3 secondary overvoltage and undervoltage faults are masked.
1 = IN4 secondary overvoltage and undervoltage faults are masked.
1 = IN5 secondary overvoltage and undervoltage faults are masked.
1 = IN6 secondary overvoltage and undervoltage faults are masked.
1 = IN7 secondary overvoltage and undervoltage faults are masked.
1 = IN1 secondary overvoltage and undervoltage faults are masked.
1 = Internal temperature sensor primary overtemperature fault masked.
1 = Remote temperature sensor 1 primary overtemperature fault masked.
1 = Remote temperature sensor 2 primary overtemperature fault masked.
1 = Internal temperature sensor secondary overtemperature fault masked.
1 = Remote temperature sensor 1 secondary overtemperature fault masked.
1 = Remote temperature sensor 2 secondary overtemperature fault masked.
1 = Current-sense primary overcurrent fault masked.
1 = Current-sense secondary overcurrent fault masked.
______________________________________________________________________________________ 29