MAX11800_1010 Datasheet, PDF (19/59 Pages) Maxim Integrated Products – Low-Power, Ultra-Small Resistive Touch-Screen Controllers with I2C/SPI Interface
Low-Power, Ultra-Small Resistive Touch-Screen
Controllers with I2C/SPI Interface
Table 2. Operating Modes, Conditions, and Options
OPERATION PSU PMC CMC TDM LPM AVG FIFO APER PUR CONT MTAG ETAG X, Y, EINT CINT COR
MODE
PUF
Z1, Z2
INT
DCM
MAX11800– Yes Yes Yes Yes No Yes No
MAX11803
No Yes Yes Yes 2 Yes 2 Yes Yes Yes No
ACM
MAX11800/ Yes 1 Yes 1 Yes 1 Yes Yes Yes Yes Yes Yes No Yes Yes Yes No No Yes
MAX11801
AUX
No Yes 3 No No — Yes 3 No No No No
No
No
No No No No
1In ACM, the choices are limited to X and Y scan, or X and Y and Z1 scan, or X and Y and Z1 and Z2 scan.
2In DCM, MTAG is always used. For DCM with CONT = 0, the following ETAGs are used: 00 = touch present (data valid), 10 = no
touch present (data may be invalid), 11 = measurement in progress (data invalid). For DCM with CONT = 1, the panel cannot be
scanned for a touch because panel setup switches are configured in a measurement mode; therefore, ETAG = 00 is used if a mea-
surement is not in progress, or ETAG = 11 if a measurement is in progress.
3A separate configuration register for delay time, sampling time, averaging, and ADC resolution settings configures the AUX input.
Pressure Measurements
Z1 and Z2 measurements determine the resistance
between the two planes within the panel sensor during
a touch (RTOUCH). Depending on the known physical
properties of the panel, one of two equations extract the
value of RTOUCH, providing information about the pres-
sure and area of the touch applied to the panel. Allow
adequate time for the panel to settle when switching
between position and pressure measurements. Figure 5
shows the physical setup of the panel when performing
pressure measurements.
Z1 and Z2 measurements allow observation of the volt-
age on either side of the effective RTOUCH resistance.
With both Z1 and Z2 measurements available, compute
RTOUCH as follows:
RTOUCH
=
RXPLATE
⎛
⎝⎜
XPOSITION
2NBITX
⎞
⎠⎟
⎛
⎝⎜
Z2
Z1
−1⎞⎠⎟
If only a Z1 measurement is available, compute
RTOUCH as follows:
RTOUCH
=
⎛
⎝⎜
RXPLA2TENBXIPTOXSITION ⎞⎠⎟
⎛
⎝⎜
2NBITZ
Z1
− 1⎞⎠⎟
−
RYPLATE
⎛⎝⎜1−
YPOSITION
2NBITY
⎞
⎠⎟
The power applied across the panel during pressure
measurements is greatly dependent on RTOUCH and
the physical position of the touch. The maximum power
dissipation in the panel during a pressure measurement
is approximately PZ = VDD2/RTOUCH. This maximum
PANEL
RTOUCH
ADC
Y+ INPUT
PANEL
RTOUCH
Y+ VDD
PANEL
RTOUCH
Y+ VDD
PANEL
RTOUCH
Y+ VDD
Y-
X-
X+
VDD
X POSITION MEASUREMENT
Y-
X-
X+
ADC
INPUT
Y POSITION MEASUREMENT
Y-
X-
X+
ADC
INPUT
Z1 PRESSURE MEASUREMENT
ADC
Y- INPUT
X-
X+
Z2 PRESSURE MEASUREMENT
Figure 4. Position Measurements
Figure 5. Pressure Measurements
______________________________________________________________________________________ 19