7.3.3 Performance - Model 705 Interface
Reference Conditions
Linearity
Measured Error
Upper Layer Dielectric
Interface Layer Dielectric
Resolution
Repeatability
Hysteresis
Response Time
Warm-up Time
Operating Temp. Range
LCD Temp. Range
Ambient Temp. Effect
Humidity
Electromagnetic Compatibility
Reflection from liquid of selected dielectric at +70° F (+20° C) with 72" probe
<0.5 inch
Upper layer ±1 inch
Interface layer ±1 inch (clean distinct interface required)
1.4–5.0
>15
±0.1 inch
<0.5 inch
<0.5 inch
<1 second
<5 seconds
-40° to +175° F (-40° to +80° C)
-5° to +160° F (-20° to +70° C)
Approximately ±0.02% of probe length/ ° C
0-99%, non-condensing
Meets CE requirements (EN-61000-6-2/2001, EN 61000-6-4/2001)
57-645 Eclipse Guided Wave Radar Transmitter - PROFIBUS PA™