English
Language : 

705-5100-F21 Datasheet, PDF (41/52 Pages) Magnetrol International, Inc. – Enhanced Model 705 with PROFIBUS PA™ Digital Output
7.3 Specifications
7.3.1 Functional
System Design
Measurement Principle
Input
Measured Variable
Zero and Span
User Interface
Keypad
Indication
Digital Communication
Minimum Operating Voltage
Quiescent Current Draw
DEV Revision
Function Blocks
Damping
Power (Measured at instrument terminals)
General Purpose/Explosion Proof
IS/FISCO/FNICO
Housing
Material
Cable Entry
Environment
Operating Temperature
Display Function Operating Temperature
Storage Temperature
Humidity
Electromagnetic Compatibility
Mounting Affects:
Shock Class
Vibration Class
Guided time-of-flight via time domain reflectometry
Level, determined by the time-of-flight of a guided radar pulse from
transmitter to product surface and back
6 inches to 75 feet (15 to 2286 cm)
3-button menu-driven data entry and system security
2-line × 8-character display
PROFIBUS PA™ Profile Version 3.0, MBP (31.25 kbits/sec)
9 VDC
15 mA
0X01
AI_1, AI_2, AI_3, AI_4
Adjustable 0-10 seconds
9 to 32 VDC (15 mA maximum current draw)
9–32 VDC (15 mA maximum current draw)
Aluminum A356T6 (<0.20% copper), optional 316 stainless steel
3⁄4" NPT and M20
-40 to +175° F (-40 to +80° C)
-5 to +160° F (-20 to +70° C)
-50 to +175° F (-40 to +80° C)
0-99%, non-condensing
Meets CE Requirements: EN 50081-2, EN 50082-2
Note: Twin Rod and Single Rod probes must be used in metallic vessel or
stillwell to maintain CE requirement.
Twin Rod: Active rod must be mounted at least 1" (25 mm) from any surface or
obstruction. Minimum stillwell diameter for Twin Rod probe is 3".
Single Rod: Nozzles do not restrict performance by ensuring the following:
No nozzle is <2" (50 mm) diameter
Ratio of Diameter: Length is 1:1 or greater;
any ratio <1:1 (e.g., a 2" × 6" nozzle = 1:3) may require a Blocking Distance
and/or DIELECTRIC adjustment
No pipe reducers are used
Obstructions
Keep conductive objects away from probe to ensure proper performance
ANSI/ISA-S71.03 Class SA1
ANSI/ISA-S71.03 Class VC2
57-645 Eclipse Guided Wave Radar Transmitter - PROFIBUS PA™
41