705-5100-F21 Datasheet, PDF (33/52 Pages) Magnetrol International, Inc. – Enhanced Model 705 with PROFIBUS PA™ Digital Output
Display
41 Compsate
42 DrateFct
xxxx
43 TargAmpl
xxxx
44 Targ Tks
xxxx
45 Targ Cal
xxxx
46 OperMode
(select)
47 7xK Corr
xxx
48 Snsr Val
xxx.x su
49 SnrCalLo
xxx.x su
50 SnrCalHi
xxx.x su
51 ProbeLvl
xxx.x plu
52 PrLvl Lo
xxx.x plu
53 PrLvl Hi
xxx.x plu
54
ElecTemp
xxx C
55
Max Temp
xxx C
56
Min Temp
xxx C
57
SZ Hyst
xx.x su
Password
Superuser
None
None
None
Superuser
Superuser
Superuser
None
Superuser
Superuser
None
Superuser
Action
Comment
Superuser Parameter
Select from None,
Manual, Auto
Diagnostic Display
Compsate = Auto, velocity
derating factor
Diagnostic Display
Compsate = Auto, target
negative threshold amplitude
Diagnostic Display
Compsate = Auto, measured time of flight
from fiducial to target
Diagnostic Display
Compsate = Auto, calibrated time of flight
from fiducial to target in room temperature air
Superuser Parameter
Compsate =
Auto, select from Run, Cal, Off
Superuser Parameter
Probe Model = 7xK, Distance in mm from
fiducial to user reference point
Distance to the target relative to the sensor
reference point.
The lower calibrated point of Sensor Value. In Sensor Units. Set to entered Probe Ln
It refers to PrLvl Lo.
The higher calibrated point of Sensor
Value. It refers to PrLvl Hi.
In Sensor Units
Level on the probe relative to the end of
the probe.
Value of PrLvl at SnrCalLo.
In Probe Level Units
Superuser Value of PrLvl at SnrCalHi.
None
Diagnostic Display
Superuser Diagnostic Display
Superuser Diagnostic Display
In Probe Level Units
Present temperature in electronics
compartment (degrees Celsius)
Maximum electronics
temperature recorded
Minimum electronics
temperature recorded
Superuser Superuser Parameter
Safety Zone hysteresis height
6.0 Diagnostic Parameters
The Eclipse Model 705 measurement engine runs through a
series of self-tests and will detect and report faulty opera-
tion. The TRANSDUCER BLOCK displays these faults in
the DEVICE_STATUS parameter. Refer to Section 7.1.2
for more information on specific faults and warnings.
When the Model 705 transmitter is initially powered on,
the measurement engine does not have enough valid meas-
urement cycles to make a decision about the output level.
For the first sixteen measurement cycles after power is
applied, the QUALITY is “Uncertain,” the SUB_STATUS
is “Initial value,” and the LIMIT attribute is “Constant.”
57-645 Eclipse Guided Wave Radar Transmitter - PROFIBUS PA™