2.5.16
IMA_TX_GRPn_TX_TEST_PATTERN (Transmit Group Tx Test Pattern)
This register contains the value of the Tx Test Pattern field for the transmitted ICP cells.
Group 1–16 Address
n=1 n=2 n=3 n=4 n=5 n=6 n=7 n=8 n=9 n=10 n=11 n=12 n=13 n=14 n=15 n=16
0x827 0x82F 0x837 0x83F 0x927 0x92F 0x937 0x93F 0xA27 0xA2F 0xA37 0xA3F 0xB27 0xB2F 0xB37 0xB3F
M28525
M28529
Group 17–32 Address
n=17 n=18 n=19 n=20 n=21 n=22 n=23 n=24 n=25 n=26 n=27 n=28 n=29 n=30 n=31 n=32
0xC27 0xC2F 0xC37 0xC3F
0xCA
7
0xCAF
0xCB 0xCBF 0xD2 0xD2F
7
7
M28525 -- Not Applicable
M28529
0xD3
7
0xD3F 0xDA
7
0xDA
F
0xDB
7
0xDB
F
Bit
Default
Name
7–0
0x0
Tx Test Pattern
Description
If the Test Link Command is set to Active, the Tx Test Pattern is sent in the ICP cell of the
Transmit Test Link. For other links and when the Test Link Command is Inactive, the Tx Test
Pattern in the Transmit ICP cells will automatically be set to 0x00. Range: 0x00–0xFF